This study was carried out to develop a potentiometric titration method in non-aqueous media for the determination of some commonly used antibiotics. For this purpose, five antibiotics, namely ampicillin, amoxycillin trihydrate, rifampin, netilmicin sulphate and ciproflaxacin hydrochloride, were potentiometrically titrated using pyridine as solvent and tetrabutylammonium hydroxide as titrant, at 25 degrees C and under a nitrogen atmosphere. The method was found to be highly accurate and precise having a relative standard deviation of less than 1.0%. Also it was shown that the method could be successfully applied to assay of commercial pharmaceuticals containing the above-mentioned antibiotics. The results of recovery studies for standard additions in pharmaceutical preparations were satisfactory. The proposed method is simple, rapid and sufficiently precise for quality control purposes.

摘要

本研究旨在开发一种非水介质中的电位滴定法,用于测定一些常用抗生素。为此,在25℃和氮气气氛下,以吡啶为溶剂、氢氧化四丁基铵为滴定剂,对氨苄西林、三水合阿莫西林、利福平、硫酸奈替米星和盐酸环丙沙星这五种抗生素进行了电位滴定。结果表明,该方法具有很高的准确度和精密度,相对标准偏差小于1.0%。此外,该方法还能成功应用于含上述抗生素的市售药品的分析。药物制剂中标准加入的回收率研究结果令人满意。所提出的方法简单、快速,且精密度足以用于质量控制目的。