Suppr超能文献

基于 N-溴代丁二酰亚胺-鲁米诺反应的流动注射化学发光法测定氨甲基苯甲酸和氨茶碱。

Flow-injection chemiluminescence determination of aminomethylbenzoic acid and aminophylline based on N-bromosuccinimide-luminol reaction.

机构信息

Department of Chemistry, Analytical Science Institute, Southwest China Normal University, Chongqing 400715, PR China.

出版信息

Talanta. 2004 Feb 27;62(3):611-7. doi: 10.1016/j.talanta.2003.09.005.

Abstract

A novel and sensitive chemiluminescence (CL) method for the determination of aminomethylbenzoic acid and aminophylline coupled with flow-injection analysis (FIA) technique is developed in this paper. It is based on the inhibition effect of the studied drugs on the chemiluminescence emission of N-bromosuccinimide-luminol (NBS-luminol) system. Under the optimum conditions, the decreased CL intensity is linear with the concentration of aminomethylbenzoic acid in the range of 2x10(-8) to 1.0x10(-6)gml(-1) and with the concentration of aminophylline in the range of 1x10(-7) to 7.0x10(-6)gml(-1), respectively. The detection limit is 7.0x10(-9)gml(-1) for aminomethylbenzoic acid (3sigma) and 3.4x10(-8)gml(-1) for aminophylline (3sigma). The relative standard deviations (R.S.D.) for 11 parallel measurements of 2.0x10(-7)gml(-1) aminomethylbenzoic acid and 1.0x10(-6)gml(-1) aminophylline are 2.6 and 3.0%, respectively. The proposed methods have been applied for the determination of the studied drugs in their pharmaceutical formulations with satisfactory results. The possible use of the proposed system for the determination of aminomethylbenzoic acid in plasma sample was also tested. The possible inhibition mechanism of aminomethylbenzoic acid and aminophylline on luminol-NBS system was discussed briefly.

摘要

本文建立了一种新的、灵敏的化学发光(CL)方法,用于结合流动注射分析(FIA)技术测定氨甲基苯甲酸和氨茶碱。该方法基于研究药物对 N-溴代琥珀酰亚胺-鲁米诺(NBS-鲁米诺)体系化学发光发射的抑制作用。在最佳条件下,CL 强度的降低与氨甲基苯甲酸在 2x10(-8)至 1.0x10(-6)gml(-1)范围内的浓度呈线性关系,与氨茶碱在 1x10(-7)至 7.0x10(-6)gml(-1)范围内的浓度呈线性关系。氨甲基苯甲酸的检测限为 7.0x10(-9)gml(-1)(3sigma),氨茶碱的检测限为 3.4x10(-8)gml(-1)(3sigma)。2.0x10(-7)gml(-1)氨甲基苯甲酸和 1.0x10(-6)gml(-1)氨茶碱的 11 次平行测量的相对标准偏差(R.S.D.)分别为 2.6%和 3.0%。该方法已应用于药物制剂中两种药物的测定,结果令人满意。还测试了该体系在测定血浆样品中氨甲基苯甲酸中的可能用途。简要讨论了氨甲基苯甲酸和氨茶碱对鲁米诺-NBS 体系的可能抑制机制。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验