Suppr超能文献

钆增强三维磁化准备快速梯度回波(3D MP-RAGE)成像在描绘脑转移瘤方面优于自旋回波成像。

Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases.

作者信息

Takeda T, Takeda A, Nagaoka T, Kunieda E, Takemasa K, Watanabe M, Hatou T, Oguro S, Katayama M

机构信息

Department of Radiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan.

出版信息

Acta Radiol. 2008 Dec;49(10):1167-73. doi: 10.1080/02841850802477924.

Abstract

BACKGROUND

Precisely defining the number and location of brain metastases is very important for establishing a treatment strategy for malignancies. Although magnetic resonance imaging (MRI) is now considered the best modality, various improvements in sequences are still being made.

PURPOSE

To prospectively compare the diagnostic ability of three-dimensional, magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging in detecting metastatic brain tumors, with that of two-dimensional spin-echo (2D SE) T1-weighted imaging.

MATERIAL AND METHODS

A total of 123 examinations were included in this study, and 119 examinations from 88 patients with known malignancies were analyzed. All patients underwent T1- and T2-weighted 2D SE transverse imaging, followed by gadolinium-enhanced T1-weighted transverse and coronal 2D SE imaging and 3D MP-RAGE transverse imaging. Four radiologists interpreted the images to compare the accuracy and the time required for interpretation for each imaging.

RESULTS

3D MP-RAGE imaging was significantly better than 2D SE imaging for detecting metastatic brain lesions, regardless of the readers' experience. The sensitivities of the 3D MP-RAGE and 2D SE imaging for all observers were 0.81 vs. 0.80 (P>0.05), specificities were 0.93 vs. 0.87 (P<0.05), positive predictive values were 0.92 vs. 0.86 (P<0.05), negative predictive values were 0.78 vs. 0.75 (P>0.05), and accuracies were 0.84 vs. 0.78 (P<0.05), respectively. There was no significant difference in the time required for image interpretation between the two modalities (15.6+/-4.0 vs. 15.4+/-4.1 min).

CONCLUSION

3D MP-RAGE imaging proved superior to 2D SE imaging in the detection of brain metastases.

摘要

背景

精确确定脑转移瘤的数量和位置对于制定恶性肿瘤的治疗策略非常重要。尽管磁共振成像(MRI)目前被认为是最佳的检查方式,但仍在对序列进行各种改进。

目的

前瞻性比较三维磁化准备快速梯度回波(3D MP-RAGE)成像与二维自旋回波(2D SE)T1加权成像检测脑转移瘤的诊断能力。

材料与方法

本研究共纳入123例检查,分析了88例已知恶性肿瘤患者的119例检查。所有患者均接受T1加权和T2加权二维自旋回波横向成像,随后进行钆增强T1加权横向和冠状二维自旋回波成像以及三维磁化准备快速梯度回波横向成像。四位放射科医生解读图像,以比较每种成像方式的准确性和解读所需时间。

结果

无论阅片者的经验如何,三维磁化准备快速梯度回波成像在检测脑转移瘤方面均显著优于二维自旋回波成像。所有观察者的三维磁化准备快速梯度回波成像和二维自旋回波成像的敏感性分别为0.81和0.80(P>0.05),特异性分别为0.93和0.87(P<0.05),阳性预测值分别为0.92和0.86(P<0.05),阴性预测值分别为0.78和0.75(P>0.05),准确性分别为0.84和0.78(P<0.05)。两种成像方式之间图像解读所需时间无显著差异(15.6±4.0与15.4±4.1分钟)。

结论

三维磁化准备快速梯度回波成像在检测脑转移瘤方面被证明优于二维自旋回波成像。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验