A novel label-free electrochemical impedimetric immunosensor for sensitive detection of ochratoxin A (OTA) was reported. A two-step reaction protocol was elaborated to modify the gold electrode. The electrode was first derivatized by electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt (4-CPDS) in acidic aqueous solution yielded stable 4-carboxyphenyl (4-CP) monolayer. The ochratoxin A antibody was then immobilized making use of the carbodiimide chemistry. The steps of the immunosensor elaboration and the immunochemical reaction between ochratoxin A and the surface-bound antibody were interrogated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect ochratoxin A. The increase in electron-transfer resistance (DeltaR(et)) values was linearly proportional to the concentration of OTA in the range of 1-20ngmL(-1), with a detection limit of 0.5ngmL(-1).

摘要

报道了一种用于灵敏检测赭曲霉毒素A(OTA)的新型无标记电化学阻抗免疫传感器。精心设计了两步反应方案来修饰金电极。首先在酸性水溶液中通过原位生成的4-羧基苯基重氮盐(4-CPDS)的电化学还原使电极衍生化,得到稳定的4-羧基苯基(4-CP)单层。然后利用碳二亚胺化学方法固定赭曲霉毒素A抗体。使用循环伏安法(CV)和电化学阻抗谱(EIS)研究了免疫传感器的制备步骤以及赭曲霉毒素A与表面结合抗体之间的免疫化学反应。利用免疫传感器表面特异性免疫相互作用引起的阻抗变化来检测赭曲霉毒素A。电子转移电阻(ΔRet)值的增加与OTA浓度在1-20 ng mL-1范围内呈线性比例关系,检测限为0.5 ng mL-1。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验