Suppr超能文献

圆锥角膜患者角膜后表面引起的高阶像差。

Higher-order aberrations due to the posterior corneal surface in patients with keratoconus.

作者信息

Nakagawa Tomoya, Maeda Naoyuki, Kosaki Ryo, Hori Yuichi, Inoue Tomoyuki, Saika Makoto, Mihashi Toshifumi, Fujikado Takashi, Tano Yasuo

机构信息

Department of Ophthalmology, Osaka University Medical School, Osaka, Japan.

出版信息

Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2660-5. doi: 10.1167/iovs.08-2754. Epub 2008 Nov 21.

Abstract

PURPOSE

This study was designed to investigate higher-order aberrations (HOAs) due to the posterior corneal surface in keratoconic eyes compared with normal eyes.

METHODS

We studied 24 normal and 28 keratoconic eyes. The anterior/posterior corneal heights and pachymetric data were obtained with a rotating Scheimpflug camera. HOAs for 6 mm pupils were calculated from the differences between the height data and the best-fit sphere, using an original program for each corneal surface. The reference axes of the measurements were aligned with the primary line of sight. The HOAs were expanded with normalized Zernike polynomials. For each pair of standard Zernike terms for trefoil, coma, tetrafoil, and secondary astigmatism, one value for the magnitude and axis was calculated by Zernike vector analysis.

RESULTS

The mean total corneal HOAs (root mean square [microm]) from the anterior/posterior surfaces were significantly (P < 0.001) higher in keratoconic (4.34/1.09, respectively) than in control eyes (0.46/0.15). The mean magnitude of each Zernike vector terms for trefoil, coma, and spherical aberration from the anterior/posterior surfaces was significantly (P < 0.001) higher in keratoconic (0.77/0.19, 3.57/0.87, -0.44/0.17) than control eyes (0.09/0.04, 0.33/0.07, 0.25/-0.07), respectively. The mean axes by vector calculation for coma due to the anterior (63.6 degrees ) and posterior surfaces (241.9 degrees ) were in opposite directions.

CONCLUSIONS

Corneal HOAs on both corneal surfaces in keratoconic eyes were higher than in control eyes. Coma from the posterior surface compensated partly for that from the anterior surface. Residual irregular astigmatism in patients with keratoconus wearing rigid gas permeable contact lenses can be estimated by measuring the HOA from the posterior corneal surface.

摘要

目的

本研究旨在调查圆锥角膜眼与正常眼相比,角膜后表面引起的高阶像差(HOAs)情况。

方法

我们研究了24只正常眼和28只圆锥角膜眼。使用旋转式Scheimpflug相机获取角膜前/后表面高度和厚度数据。对于6mm瞳孔,利用针对每个角膜表面的原始程序,根据高度数据与最佳拟合球面之间的差异计算HOAs。测量的参考轴与主要视线对齐。HOAs用归一化的泽尼克多项式展开。对于三叶形、彗差、四叶形和继发性散光的每对标准泽尼克项,通过泽尼克矢量分析计算一个大小和轴的值。

结果

圆锥角膜眼(分别为4.34/1.09)前/后表面的平均总角膜HOAs(均方根[微米])显著高于对照眼(0.46/0.15)(P < 0.001)。圆锥角膜眼前/后表面的三叶形、彗差和球差的每个泽尼克矢量项的平均大小(分别为0.77/0.19、3.57/0.87、-0.44/0.17)显著高于对照眼(0.09/0.04、0.33/0.07、0.25/-0.07)(P < 0.001)。通过矢量计算,前表面(63.6度)和后表面(241.9度)引起的彗差平均轴方向相反。

结论

圆锥角膜眼两个角膜表面的角膜HOAs均高于对照眼。后表面的彗差部分补偿了前表面的彗差。佩戴硬性透气性角膜接触镜的圆锥角膜患者的残余不规则散光可通过测量角膜后表面的HOA来估计。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验