Suppr超能文献

未佩戴和已佩戴的硅水凝胶隐形眼镜的动态体外脱水模式。

Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.

作者信息

González-Méijome J M, López-Alemany A, Almeida J B, Parafita M A

机构信息

Department of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal.

出版信息

J Biomed Mater Res B Appl Biomater. 2009 Jul;90(1):250-8. doi: 10.1002/jbm.b.31279.

Abstract

PURPOSE

To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure.

METHODS

Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared between worn and unworn samples.

RESULTS

The quantitative parameters derived from the dehydration curves showed statistically significant differences between worn and unworn lenses regarding the initial dehydration rate and ability to maintain their original hydration. Worn lenses showed shorter phase I duration (decreased by 30 to 60% compared to unworn samples), a significantly faster initial dehydration rate (increased by about 1%/minute), and lower water retention index (decreased by 10 to 20%) as derived from the initial cumulative dehydration. All the differences were statistically significant for all lenses (p < 0.05).

CONCLUSION

The initial dehydration rates were significantly increased in all CL after wear. This could be of clinical interest because it represents the average initial dehydration rates during the first moments when the lens is left to dehydrate after a blink. This study suggests that even after the lenses had been equilibrated in saline solution for several days, the materials lose their ability to retain water.

摘要

目的

使用先前描述的重量法评估磨损对硅水凝胶(Si-Hi)隐形眼镜(CL)体外动态脱水的影响。

方法

五款不同的硅水凝胶(Si-Hi)隐形眼镜(CL)在患者日常佩戴条件下佩戴15天至1个月后进行评估。每天佩戴后,镜片用多功能护理液进行护理和消毒。将镜片置于温度和相对湿度可控的分析天平中使其脱水,并将结果与相同屈光度和材质的新镜片样本数据进行比较。获取了几个定量参数,并对佩戴和未佩戴的样本进行了比较。

结果

从脱水曲线得出的定量参数显示,佩戴和未佩戴的镜片在初始脱水速率和保持原始水合能力方面存在统计学上的显著差异。佩戴过的镜片I期持续时间较短(与未佩戴的样本相比减少了30%至60%),初始脱水速率明显更快(增加了约1%/分钟),并且从初始累积脱水中得出的保水指数更低(降低了10%至20%)。所有镜片的所有差异均具有统计学意义(p < 0.05)。

结论

所有隐形眼镜佩戴后初始脱水速率均显著增加。这可能具有临床意义,因为它代表了眨眼后镜片开始脱水的最初时刻的平均初始脱水速率。本研究表明,即使镜片在盐溶液中平衡了数天,材料仍会失去保水能力。