Suppr超能文献

牙髓治疗期间使用传统成像与间接数字成像获得的影像学测量结果比较。

Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment.

作者信息

Schmitd Ligia Buloto, Lima Tatiana de Castro, Chinellato Luiz Eduardo Montenegro, Bramante Clóvis Monteiro, Garcia Roberto Brandão, de Moraes Ivaldo Gomes, Bernardineli Norberti

机构信息

Department of Stomatology, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil.

出版信息

J Appl Oral Sci. 2008 Mar-Apr;16(2):167-70. doi: 10.1590/s1678-77572008000200016.

Abstract

The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora system (p<0.01). The measurements achieved by the investigated radiographic methods were clinically similar and they are thus equivalent. Changes in brightness and contrast of the images using Digora software improved the diagnosis.

摘要

本研究的目的是评估牙髓治疗过程中拍摄的间接数字化根尖片的质量,并将该技术记录的测量值与传统根尖片获得的测量值进行比较。对在包鲁牙科学院本科牙髓病诊所拍摄的200张传统根尖片进行了数字化处理。三位检查者对传统根尖片和间接数字化图像在牙髓治疗过程中记录的测量值的质量和准确性、根管长度测定、牙胶尖适配、侧向加压充填和最终充填情况进行了比较。传统根尖片在由黑卡纸环绕的观片灯上观察,并用放大镜和毫米尺测量;间接数字化图像在Digora for Windows软件上进行评估,可自由使用亮度/对比度工具。与传统根尖片不同,所有间接数字化图像均被认为质量较高。Digora系统中,充填材料与根尖之间的距离平均大0.117 mm(p<0.01)。所研究的根尖片方法获得的测量值在临床上相似,因此是等效的。使用Digora软件改变图像的亮度和对比度可改善诊断。

相似文献

2
3
Quality of root canal treatment performed by undergraduate dental students at the University of Khartoum, Sudan.
Aust Endod J. 2011 Aug;37(2):56-60. doi: 10.1111/j.1747-4477.2010.00273.x. Epub 2010 Oct 24.
4
Impact of three radiographic methods in the outcome of nonsurgical endodontic treatment: a five-year follow-up.
J Endod. 2013 Sep;39(9):1097-103. doi: 10.1016/j.joen.2013.04.002. Epub 2013 May 21.
6
Is endodontic treatment performed under general anaesthesia technically acceptable?
Clin Oral Investig. 2012 Dec;16(6):1599-606. doi: 10.1007/s00784-011-0663-3. Epub 2011 Dec 24.
7
In vivo performance of the new non-instrumentation technology (NIT) for root canal obturation.
Int Endod J. 2002 Apr;35(4):352-8. doi: 10.1046/j.1365-2591.2002.00484.x.
8
Evaluation of the quality of different endodontic obturation techniques by digital radiography.
Clin Oral Investig. 2013 Jan;17(1):97-103. doi: 10.1007/s00784-012-0675-7. Epub 2012 Jan 19.
9
Working length determination in general dental practice: a randomised controlled trial.
Br Dent J. 2011 Dec 23;211(12):595-8. doi: 10.1038/sj.bdj.2011.1052.
10
Evaluation of interference of calcium hydroxide-based intracanal medication in filling root canal systems.
J Contemp Dent Pract. 2011 Sep 1;12(5):368-71. doi: 10.5005/jp-journals-10024-1061.

引用本文的文献

3
Usage of Image-Enhancement Tools When Reading Radiographs Taken During Root-Canals Treatments' Procedures.
Eur Endod J. 2020 Feb 13;5(2):94-104. doi: 10.14744/eej.2019.62634. eCollection 2020.
6
The Effects of Imaging Enhancement Tools in the Detection of Horizontal Root Fractures.
J Clin Diagn Res. 2017 Aug;11(8):ZC98-ZC101. doi: 10.7860/JCDR/2017/26775.10490. Epub 2017 Aug 1.
7
Effect of Contrast Inversion Enhancement on the Accuracy of Endodontic File Length Determination in Digital Radiography.
J Clin Diagn Res. 2015 May;9(5):ZC102-5. doi: 10.7860/JCDR/2015/11767.5988. Epub 2015 May 1.
8
Film and digital periapical radiographs for the measurement of apical root shortening.
J Clin Exp Dent. 2012 Dec 1;4(5):e281-5. doi: 10.4317/jced.50872.
9
Effect of digital noise reduction on the accuracy of endodontic file length determination.
Imaging Sci Dent. 2013 Sep;43(3):185-90. doi: 10.5624/isd.2013.43.3.185. Epub 2013 Sep 23.

本文引用的文献

1
Digital and advanced imaging in endodontics: a review.
J Endod. 2007 Jan;33(1):1-6. doi: 10.1016/j.joen.2006.08.013.
2
Conventional radiographs vs digitized radiographs: image quality assessment.
Dentomaxillofac Radiol. 2005 Nov;34(6):353-6. doi: 10.1259/dmfr/99611204.
3
The digital revolution, images and X-rays.
N Y State Dent J. 2005 Jan;71(1):40-3.
5
The deal on digital: the status of radiographic imaging.
Compend Contin Educ Dent. 2001 Dec;22(12):1057-62; quiz 1064.
6
Measurement of endodontic file lengths: calibrated versus uncalibrated digital images.
J Endod. 2001 Dec;27(12):779-81. doi: 10.1097/00004770-200112000-00017.
7
Three phosphor plate systems and film compared for imaging root canals.
Int Endod J. 2001 Jun;34(4):275-9. doi: 10.1046/j.1365-2591.2001.00380.x.
8
Intra-oral storage phosphor and conventional radiography in the assessment of alveolar bone structures.
Dentomaxillofac Radiol. 2000 Nov;29(6):362-7. doi: 10.1038/sj/dmfr/4600556.
9
10
Reduction in size of digital images: does it lead to less detectability or loss of diagnostic information?
Dentomaxillofac Radiol. 1998 Mar;27(2):93-6. doi: 10.1038/sj/dmfr/4600329.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验