Suppr超能文献

Descemet膜剥除自动内皮角膜移植术后的屈光变化及其与植片厚度和直径的相关性。

Refractive change after descemet stripping automated endothelial keratoplasty surgery and its correlation with graft thickness and diameter.

作者信息

Jun Bokkwan, Kuo Anthony N, Afshari Natalie A, Carlson Alan N, Kim Terry

机构信息

Corneal and Refractive Surgery Services, Department of Ophthalmology, Duke University School of Medicine, Durham, NC 27710, USA.

出版信息

Cornea. 2009 Jan;28(1):19-23. doi: 10.1097/ICO.0b013e318182a4c1.

Abstract

PURPOSE

The purpose of this study was to evaluate the refractive change after Descemet stripping automated endothelial keratoplasty (DSAEK) surgery and its correlation with graft thickness and diameter.

METHODS

We retrospectively analyzed the refractive outcomes of 45 cases of DSAEK surgery that were performed at Duke University Eye Center between August 2005 and December 2006. We divided our study groups into DSAEK triple cases and pseudophakic DSAEK cases. We measured manifest refraction preoperatively and postoperatively in each group and compared the difference between the preoperative and the postoperative spherical equivalent. We evaluated the correlation of the refractive change with graft thickness and diameter.

RESULTS

Forty-five DSAEK cases in 44 patients (27 women and 17 men) were evaluated and analyzed. Mean age of the patients at surgery was 67.6 years (15-81 years, SD 10.7 years). Forty cases were treated for Fuchs endothelial dystrophy and 5 for pseudophakic bullous keratopathy/bullous keratopathy. Seventeen cases were DSAEK triple cases and 28 pseudophakic DSAEK cases. In the DSAEK triple group, the mean change in refraction at an average of 4 months postoperatively was +1.15 D (range -0.02 to 2.87, SD 1.15). In the pseudophakic DSAEK group, the mean change in refraction at an average of 5 months postoperatively was +0.71 D (range -1.75 to 3.0, SD 1.11). The overall refractive change was +0.88 D (range -1.75 to 3.0, SD 1.02). Correlation of refractive change with graft diameter was modest (r = 0.29, P = 0.05), and a small correlation was found with respect to graft thickness (r = -0.16, P = 0.31).

CONCLUSIONS

Our study of DSAEK grafts demonstrated a hyperopic refractive shift after DSAEK surgery. This observation should be taken into consideration when deciding on the appropriate intraocular lens power in DSAEK triple surgery and may also aid in anticipating refractive outcomes after pseudophakic DSAEK surgery. Further studies to follow these refractive changes over a longer follow-up period and to investigate the mechanism of this refractive change after DSAEK surgery are warranted.

摘要

目的

本研究旨在评估深板层角膜内皮移植术(DSAEK)手术后的屈光变化及其与植片厚度和直径的相关性。

方法

我们回顾性分析了2005年8月至2006年12月在杜克大学眼科中心进行的45例DSAEK手术的屈光结果。我们将研究组分为DSAEK三联手术病例和人工晶状体眼DSAEK病例。我们测量了每组术前和术后的显验光,并比较了术前和术后等效球镜度的差异。我们评估了屈光变化与植片厚度和直径的相关性。

结果

对44例患者(27例女性和17例男性)的45例DSAEK病例进行了评估和分析。患者手术时的平均年龄为67.6岁(15 - 81岁,标准差10.7岁)。40例因Fuchs内皮营养不良接受治疗,5例因人工晶状体眼大泡性角膜病变/大泡性角膜病变接受治疗。17例为DSAEK三联手术病例,28例为人工晶状体眼DSAEK病例。在DSAEK三联手术组中,术后平均4个月时的平均屈光变化为+1.15 D(范围 -0.02至2.87,标准差1.15)。在人工晶状体眼DSAEK组中,术后平均5个月时的平均屈光变化为+0.71 D(范围 -1.75至3.0,标准差1.11)。总体屈光变化为+0.88 D(范围 -1.75至3.0,标准差1.02)。屈光变化与植片直径的相关性中等(r = 0.29,P = 0.05),与植片厚度的相关性较小(r = -0.16,P = 0.31)。

结论

我们对DSAEK植片的研究表明,DSAEK手术后出现远视性屈光偏移。在决定DSAEK三联手术中合适的人工晶状体度数时应考虑这一观察结果,这也可能有助于预测人工晶状体眼DSAEK手术后的屈光结果。有必要进行进一步的研究,以在更长的随访期内跟踪这些屈光变化,并研究DSAEK手术后这种屈光变化的机制。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验