Suppr超能文献

Pentacam对后弹力层移植片的评估,以解释Descemet膜剥脱自动内皮角膜移植术后的远视化现象。

Pentacam assessment of posterior lamellar grafts to explain hyperopization after Descemet's stripping automated endothelial keratoplasty.

作者信息

Scorcia Vincenzo, Matteoni Stefania, Scorcia Giovanni Battista, Scorcia Giovanni, Busin Massimo

机构信息

Casa di Cura Villa Serena, Department of Ophthalmology, Forlì, Italy.

出版信息

Ophthalmology. 2009 Sep;116(9):1651-5. doi: 10.1016/j.ophtha.2009.04.035. Epub 2009 Jul 29.

Abstract

PURPOSE

To evaluate changes in posterior corneal curvature as a possible cause of the hyperopic refractive shift observed after Descemet's stripping automated endothelial keratoplasty (DSAEK).

DESIGN

Prospective, noncomparative, interventional case series.

PARTICIPANTS

Thirty-four eyes of 29 patients with Fuchs' endothelial dystrophy or pseudophakic bullous keratopathy.

METHODS

A standard DSAEK procedure was performed in 34 eyes using the pull-through technique for graft delivery. When cataract was present (n = 7), phacoemulsification with posterior chamber intraocular lens implantation was combined. Each eye underwent Pentacam (Oculus, Wetzlar, Germany) evaluation 1, 3, and 12 months after surgery. Corneal graft thickness was calculated on Scheimpflug scans at 9 locations (1 central, 4 peripheral, and 4 mid peripheral). The mean radius of posterior corneal curvature (Rm) was recorded. At each postoperative examination time, manifest refraction was determined and compared with pre-DSAEK values in simple procedures or with intended postoperative refraction, if cataract surgery had been performed.

MAIN OUTCOME MEASURES

Manifest refraction, Rm, and corneal graft thickness at 1, 3, and 12 months after surgery.

RESULTS

The mean+/-standard deviation posterior corneal curvature was 6.5+/-0.56 mm before surgery and varied from 5.52+/-0.39 mm 1 month after surgery to 5.83+/-0.37 mm at 3 months after surgery and 5.92+/-0.35 mm at 12 months after surgery. The grafts were significantly thicker in the periphery and mid periphery than in the center at all examination times. Thickening diminished significantly over time at all locations. The average reduction of corneal thickness was higher at the edges (91.5 microm) than in the mid periphery (38.3 microm) or in the center (24.2 microm). The average postoperative spherical equivalent+/-standard deviation changed from -0.31+/-2.35 diopters (D) before surgery to 1.03+/-2.21 D 1 month after surgery, 0.61+/-2.07 D 3 months after surgery, and +0.31+/-2.03 D 12 months after surgery.

CONCLUSIONS

The difference in thickness between center and periphery of the DSAEK graft induces a change in posterior corneal curvature, resulting in a hyperopic shift that decreases with time and is negligible for spectacle correction. However, when performing a triple procedure, intraocular lens selection should take into account the refractive change induced by DSAEK.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

摘要

目的

评估后角膜曲率变化作为Descemet膜剥除自动内皮角膜移植术(DSAEK)后观察到的远视性屈光偏移可能原因的情况。

设计

前瞻性、非对照、干预性病例系列。

参与者

29例患有Fuchs内皮营养不良或假晶状体大泡性角膜病变患者的34只眼。

方法

对34只眼采用拉过技术进行标准DSAEK手术以植入移植物。当存在白内障时(n = 7),联合进行白内障超声乳化吸除及后房型人工晶状体植入术。每只眼在术后1、3和12个月接受Pentacam(德国韦茨拉尔奥culus公司)评估。在9个位置(1个中央、4个周边和4个中周边)的Scheimpflug扫描上计算角膜移植物厚度。记录后角膜曲率的平均半径(Rm)。在每次术后检查时,确定显验光并与DSAEK手术前的简单程序值或如果进行了白内障手术则与预期的术后验光进行比较。

主要观察指标

术后1、3和12个月的显验光、Rm和角膜移植物厚度。

结果

术前平均±标准差后角膜曲率为6.5±0.56 mm,术后1个月为5.52±0.39 mm,术后3个月为5.83±0.37 mm,术后12个月为5.92±0.35 mm。在所有检查时间,移植物在周边和中周边明显比中央厚。随着时间推移,所有位置的增厚均显著减少。角膜厚度的平均减少在边缘(91.5微米)高于中周边(38.3微米)或中央(24.2微米)。术后平均球镜等效度±标准差从术前的-0.31±2.35屈光度(D)变为术后1个月的1.03±2.21 D,术后3个月的0.61±2.07 D,术后12个月的+0.31±2.03 D。

结论

DSAEK移植物中央和周边厚度的差异导致后角膜曲率改变,从而引起远视性偏移,该偏移随时间减少且对眼镜矫正可忽略不计。然而,在进行三联手术时,人工晶状体的选择应考虑DSAEK引起的屈光变化。

财务披露

专有或商业披露可在参考文献之后找到。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验