Ehli Erik A, Lengyel-Nelson Timea, Hudziak James J, Davies Gareth E
Avera Institute for Human Behavioral Genetics, Avera Behavioral Health Center, Sioux Falls, SD, USA.
BMC Res Notes. 2008 Dec 22;1:133. doi: 10.1186/1756-0500-1-133.
We sought to describe the integrity of human genomic DNA extracted from saliva saturated cotton spit wads stored at -20 degrees C for approximately 11 years. 783 spit wad samples were collected from an ADHD sample population (Vermont Family Study) during 1996-2000. Human genomic DNA was extracted from the spit wads using a commercially available kit; QIAamp DNA Blood Midi Kit (Qiagen, Inc., Valencia, CA.) with a few modifications.
The resulting DNA yield was more than adequate for genetic analysis and ranged from approximately 1 mug to a total of 80 mug (mean 17.3 mugs +/- 11.9 mugs). A260/A280 ratios for the human genomic DNA extracted from the spit wads was consistently within the generally acceptable values of 1.7-2.0, with the lowest purity being 1.70, and a mean value of 1.937 +/- 0.226 for the 783 samples. The DNA also was suitable for PCR reactions as evidenced by the amplification of the serotonin-transporter-linked polymorphic region, 5HTTLPR. 5HTTLPR is a functional polymorphism in the promoter region of the serotonin transporter gene (HTT, SLC6A4, or SERT), consisting of two intensively studied alleles. 770 of the 783 samples (98.3%) produced fragments after PCR of the expected size with primers specific for 5HTTLPR.
High quality and abundant genomic DNA can be successfully retrieved from saliva saturated cotton spit wads using the commercially available kit, QIAamp DNA Blood Midi Kit from Qiagen, Inc. Furthermore, the DNA can be extracted in less than 3 hours and multiple samples can be processed simultaneously thus reducing processing time.
我们试图描述从储存在-20℃约11年的唾液饱和棉拭子中提取的人类基因组DNA的完整性。1996年至2000年期间,从一个注意力缺陷多动障碍样本群体(佛蒙特家庭研究)中收集了783个拭子样本。使用市售试剂盒从拭子中提取人类基因组DNA;即Qiagen公司(加利福尼亚州瓦伦西亚)的QIAamp DNA Blood Midi试剂盒,并做了一些修改。
所得DNA产量足以进行基因分析,范围从约1微克到总共80微克(平均17.3微克±11.9微克)。从拭子中提取的人类基因组DNA的A260/A280比值始终在通常可接受的1.7 - 2.0范围内,最低纯度为1.70,783个样本的平均值为1.937±0.226。DNA也适用于PCR反应,血清素转运体相关多态性区域5HTTLPR的扩增证明了这一点。5HTTLPR是血清素转运体基因(HTT、SLC6A4或SERT)启动子区域的一种功能多态性,由两个经过深入研究的等位基因组成。783个样本中的770个(98.3%)在使用针对5HTTLPR的特异性引物进行PCR后产生了预期大小的片段。
使用Qiagen公司的市售试剂盒QIAamp DNA Blood Midi Kit可以成功地从唾液饱和棉拭子中提取高质量且丰富的基因组DNA。此外,DNA可以在不到3小时内提取出来,并且可以同时处理多个样本,从而减少了处理时间。