Abstract

OBJECTIVE

The purpose of this study was to evaluate the reliability of the vestibular evoked myogenic potential (VEMP) response in a clinical setting when only a feedback mechanism is available for monitoring background EMG.

METHODS

Sixty-one healthy subjects participated in the investigation of the within-session reliability, whereas fourteen of them were retested after one week for examination of the between-session reliability. VEMPs were recorded using 500 Hz tone bursts with the subjects in a sitting position and their heads turned away from the test ear to the contralateral shoulder, thereby pushing their chin against the inflatable cuff of a blood pressure manometer, serving as feedback method.

RESULTS

The feedback method revealed latency and amplitude values comparable to other data in the literature where different test conditions were applied. Excellent reliability with ICC values ranging from 0.78 to 0.96 and CV(ME) values ranging from 4% to 36%, was achieved for P1 and N1 latency, threshold and interpeak amplitude. Good reliability with ICC values of 0.65 and 0.68 and CV(ME) values of 170% and 189%, was obtained for the asymmetry ratio.

CONCLUSIONS

A unilateral muscle contraction controlled by a feedback mechanism resulted in reliable response parameters, comparable right to left and corresponding to literature data obtained in different test conditions.

SIGNIFICANCE

The use of a blood pressure manometer as feedback mechanism combined with a meticulously controlled positioning of the head and contraction of the SCM muscle provides a reliable alternative in clinical settings, when the background muscle contraction cannot be measured or software related correction algorithms are not accessible.

摘要

目的

本研究的目的是评估在临床环境中,当仅有一种反馈机制可用于监测背景肌电图时,前庭诱发肌源性电位(VEMP)反应的可靠性。

方法

61名健康受试者参与了会话内可靠性的研究,其中14人在一周后重新进行测试以检查会话间可靠性。使用500Hz的短纯音记录VEMP,受试者坐姿,头部从测试耳转向对侧肩部,从而将下巴抵在血压计的充气袖带上,作为反馈方法。

结果

该反馈方法显示的潜伏期和波幅数值与文献中应用不同测试条件时的其他数据相当。P1和N1潜伏期、阈值和峰间波幅的组内相关系数(ICC)值范围为0.78至0.96,测量误差的变异系数(CV(ME))值范围为4%至36%,可靠性极佳。不对称率的ICC值分别为0.65和0.68,CV(ME)值分别为170%和189%,可靠性良好。

结论

由反馈机制控制的单侧肌肉收缩产生了可靠的反应参数,左右侧相当,且与在不同测试条件下获得的文献数据相符。

意义

当无法测量背景肌肉收缩或无法使用软件相关校正算法时,使用血压计作为反馈机制并结合精心控制的头部位置和胸锁乳突肌收缩,在临床环境中提供了一种可靠的替代方法。