Suppr超能文献

体内白内障超声乳化三个模拟步骤中的眼压及计算得出的舒张期眼灌注压。

Intraocular pressure and calculated diastolic ocular perfusion pressure during three simulated steps of phacoemulsification in vivo.

作者信息

Zhao Yune, Li Xingyu, Tao Aizhu, Wang Jianhua, Lu Fan

机构信息

School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China.

出版信息

Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2927-31. doi: 10.1167/iovs.08-2996. Epub 2009 Jan 24.

Abstract

PURPOSE

To investigate the fluctuations of directly measured intraocular pressure (IOP) and induced diastolic ocular perfusion pressure (DOPP) during three simulated steps of phacoemulsification in vivo.

METHODS

Twenty-five eyes of 25 patients who underwent phacoemulsification were evaluated. A pressure transducer was inserted into the anterior chamber to measure IOP directly. The cortical cleanup and viscoelastic removal, nuclear disassembly, and anterior capsular polishing stages of phacoemulsification were simulated. Baseline, static, and dynamic IOP measurements at each stage were conducted before a routine phacoemulsification procedure was performed. DOPP was determined as the difference between diastolic blood pressure and IOP.

RESULTS

The directly measured IOP fluctuated from 13 +/- 4.7 to 96 +/- 6.2 mm Hg during the simulated steps of phacoemulsification (repeated-measurement ANOVA, P < 0.001). It was elevated more than 39 mm Hg compared with the baseline in static and dynamic measurements (post hoc, P < 0.001). Static DOPPs were lower than 0 mm Hg in all cases during simulated cortical cleanup and viscoelastic removal and in 19 cases during simulated nuclear disassembly. Dynamic DOPPs were lower than 0 mm Hg in 14 cases during simulated cortical cleanup and viscoelastic removal.

CONCLUSIONS

IOP and DOPP fluctuate widely during simulated steps of phacoemulsification. Further studies may be needed to establish the effect of the transient fluctuations in DOPP on visual function.

摘要

目的

研究在体内超声乳化三个模拟步骤中直接测量的眼压(IOP)和诱导的舒张期眼灌注压(DOPP)的波动情况。

方法

对25例行超声乳化术的患者的25只眼进行评估。将压力传感器插入前房以直接测量眼压。模拟超声乳化的皮质清除和粘弹剂清除、核分解以及前囊抛光阶段。在进行常规超声乳化手术前,在每个阶段进行基线、静态和动态眼压测量。DOPP被确定为舒张压与眼压之间的差值。

结果

在超声乳化模拟步骤中,直接测量的眼压在13±4.7至96±6.2 mmHg之间波动(重复测量方差分析,P<0.001)。在静态和动态测量中,与基线相比升高超过39 mmHg(事后检验,P<0.001)。在模拟皮质清除和粘弹剂清除的所有病例以及模拟核分解的19例病例中,静态DOPP均低于0 mmHg。在模拟皮质清除和粘弹剂清除过程中,14例病例的动态DOPP低于0 mmHg。

结论

在超声乳化模拟步骤中,眼压和DOPP波动较大。可能需要进一步研究来确定DOPP的短暂波动对视觉功能的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验