J Physiol Pharmacol. 2008 Dec;59 Suppl 6:401-6.

Abstract

Many patients with obstructive sleep apnea syndrome (OSAS) receiving continuous positive airway pressure (CPAP) complain of leaky masks or too high pressure during expiration. C-Flex is a breathing mode with a constant CPAP pressure during inspiration and a reduced pressure during expiration. We compared the leakage data between CPAP and C-Flex and their influence on patients' compliance. Thirty patients (22 men, 8 women, aged 55.4 +/- 11.7 yr, BMI 32.0 +/- 7.4 kg/m(2)) with polysomnographically diagnosed OSAS got a CPAP or C-Flex therapy in a randomized double-blind and cross-over design. After 6 weeks, an adjustment to the other mode followed. Leakage data were sampled during all polysomnographic examinations. Twelve patients dropped out of the study (7 after C-Flex, 5 after CPAP), 4 of them gave up CPAP therapy completely (2 after CPAP, 2 after C-Flex). The leakage in CPAP mode was 27.5 +/-11.5 l/min and in C-Flex mode 28.0 +/-10 l/min (ns). The average nightly use in CPAP mode was 350.0 +/- 70.2 min and in C-Flex mode 347.0 +/- 70.8 min (ns). In the final decision of therapy, 9 patients chose C-Flex and 4 patients CPAP (P=0.001). Five patients had no preference regarding the therapy mode. There is no difference in leakage and compliance between CPAP and C-Flex. But significantly more patients decided for a therapy with the C-Flex mode. There must be other unknown factors that influence the decision for the mode of therapy.

摘要

许多接受持续气道正压通气(CPAP)治疗的阻塞性睡眠呼吸暂停综合征(OSAS)患者抱怨面罩漏气或呼气时压力过高。C-Flex是一种呼吸模式,吸气时CPAP压力恒定,呼气时压力降低。我们比较了CPAP和C-Flex之间的漏气数据及其对患者依从性的影响。30例经多导睡眠图诊断为OSAS的患者(22例男性,8例女性,年龄55.4±11.7岁,体重指数32.0±7.4kg/m²)采用随机双盲交叉设计接受CPAP或C-Flex治疗。6周后,改用另一种模式。在所有多导睡眠图检查期间采集漏气数据。12例患者退出研究(7例在C-Flex治疗后,5例在CPAP治疗后),其中4例完全放弃CPAP治疗(2例在CPAP治疗后,2例在C-Flex治疗后)。CPAP模式下的漏气量为27.5±11.5升/分钟,C-Flex模式下为28.0±10升/分钟(无显著差异)。CPAP模式下平均每晚使用时间为350.0±70.2分钟,C-Flex模式下为347.0±70.8分钟(无显著差异)。在最终的治疗选择中,9例患者选择C-Flex,4例患者选择CPAP(P=0.001)。5例患者对治疗模式无偏好。CPAP和C-Flex在漏气和依从性方面没有差异。但明显更多的患者选择了C-Flex模式治疗。一定有其他未知因素影响治疗模式的选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验