Clear fuse quartz (CFQ) could be a good candidate for dose measurements in the radiation processing of food material and in the sterilization of disposable medical and pharmaceutical products. In this study, bulk samples of CFQ materials were exposed to 10 MeV electrons at doses between 5-15 and 25-35 kGy; the dose ranges normally used for processing and sterilization. After irradiation, the samples were subjected to electron spin resonance analysis to test the intensity of their signal against the applied doses. The reproducibility of dose curve of the material to 10 MeV electrons was also studied, in which the dosed samples were annealed at 800 degrees C for 20 min and reused for further dose curve reproducibility investigation. The dose response curves of the reused samples showed a good linearity between the absorbed dose and the ESR intensity of the signals. They also indicated that the ESR intensity in the dose response curve, in both dose ranges, decreased by approximately 37% for the first reuse process and approximately 41% for the second reuse process of the samples in comparison to the first measurement. The thermal fading of the cylindrical samples of the CFQ, at room temperature, showed a sharp decay of approximately 20% over a period of 15 days, after which the decay-rate was negligible for a measured period of 60 days.
透明熔凝石英(CFQ)可能是食品材料辐射加工以及一次性医疗和药品灭菌剂量测量的理想候选材料。在本研究中,CFQ材料的块状样品被暴露于剂量范围为5 - 15 kGy和25 - 35 kGy的10 MeV电子束下;这些剂量范围通常用于加工和灭菌。辐照后,对样品进行电子自旋共振分析,以测试其信号强度与所施加剂量的关系。还研究了该材料对10 MeV电子剂量曲线的可重复性,其中将已辐照的样品在800℃下退火20分钟,然后重新用于进一步的剂量曲线可重复性研究。重复使用样品的剂量响应曲线显示,吸收剂量与信号的电子自旋共振强度之间具有良好的线性关系。它们还表明,在两个剂量范围内,与首次测量相比,样品在第一次重复使用过程中剂量响应曲线的电子自旋共振强度下降了约37%,在第二次重复使用过程中下降了约41%。CFQ圆柱形样品在室温下的热褪色在15天内显示出约20%的急剧衰减,之后在60天的测量期内衰减率可忽略不计。