Suppr超能文献

通过概率治疗计划降低调强质子治疗(IMPT)计划对摆位误差和射程不确定性的敏感性。

Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning.

作者信息

Unkelbach Jan, Bortfeld Thomas, Martin Benjamin C, Soukup Martin

机构信息

Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, USA.

出版信息

Med Phys. 2009 Jan;36(1):149-63. doi: 10.1118/1.3021139.

Abstract

Treatment plans optimized for intensity modulated proton therapy (IMPT) may be very sensitive to setup errors and range uncertainties. If these errors are not accounted for during treatment planning, the dose distribution realized in the patient may by strongly degraded compared to the planned dose distribution. The authors implemented the probabilistic approach to incorporate uncertainties directly into the optimization of an intensity modulated treatment plan. Following this approach, the dose distribution depends on a set of random variables which parameterize the uncertainty, as does the objective function used to optimize the treatment plan. The authors optimize the expected value of the objective function. They investigate IMPT treatment planning regarding range uncertainties and setup errors. They demonstrate that incorporating these uncertainties into the optimization yields qualitatively different treatment plans compared to conventional plans which do not account for uncertainty. The sensitivity of an IMPT plan depends on the dose contributions of individual beam directions. Roughly speaking, steep dose gradients in beam direction make treatment plans sensitive to range errors. Steep lateral dose gradients make plans sensitive to setup errors. More robust treatment plans are obtained by redistributing dose among different beam directions. This can be achieved by the probabilistic approach. In contrast, the safety margin approach as widely applied in photon therapy fails in IMPT and is neither suitable for handling range variations nor setup errors.

摘要

为强度调制质子治疗(IMPT)优化的治疗计划可能对摆位误差和射程不确定性非常敏感。如果在治疗计划期间未考虑这些误差,那么与计划剂量分布相比,患者体内实际实现的剂量分布可能会严重退化。作者采用概率方法将不确定性直接纳入强度调制治疗计划的优化过程中。按照这种方法,剂量分布取决于一组对不确定性进行参数化的随机变量,用于优化治疗计划的目标函数也是如此。作者对目标函数的期望值进行优化。他们研究了关于射程不确定性和摆位误差的IMPT治疗计划。他们证明,与不考虑不确定性的传统计划相比,将这些不确定性纳入优化会产生定性上不同的治疗计划。IMPT计划的敏感性取决于各个射束方向的剂量贡献。大致而言,射束方向上陡峭的剂量梯度会使治疗计划对射程误差敏感。陡峭的横向剂量梯度会使计划对摆位误差敏感。通过在不同射束方向之间重新分配剂量可获得更稳健的治疗计划。这可以通过概率方法实现。相比之下,广泛应用于光子治疗的安全裕度方法在IMPT中失效,既不适用于处理射程变化,也不适用于处理摆位误差。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验