Suppr超能文献

技术说明:一种用于猪营养吸收动力学和定量长期研究的改进手术模型。

Technical note: An improved surgical model for the long-term studies of kinetics and quantification of nutrient absorption in swine.

作者信息

Hooda S, Matte J J, Wilkinson C W, Zijlstra R T

机构信息

Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada T6G 2P5.

出版信息

J Anim Sci. 2009 Jun;87(6):2013-9. doi: 10.2527/jas.2008-1423. Epub 2009 Feb 27.

Abstract

An improved technique to study kinetics and quantitative absorption of nutrients in pigs is described. Three female pigs (35 kg of BW) were surgically modified with catheters in the hepatic portal vein and carotid artery and an ultrasonic flow probe around the portal vein. Catheter placement and patency was secured using distal modifications (rings and holes) and nonabsorbable suture. Catheters and flow probe cable were tunneled subcutaneously after exteriorization for further protection. Fibrosis and adhesions in the body cavity were minimized by avoiding excessive manipulation and drying of viscera. Pigs were supported during recovery by intravenous fluid therapy of AA and electrolytes until regular feeding resumed. Catheters were flushed daily with heparinized saline (200 IU/L). After 10 d, pigs were fed a diet based on wheat and soybean meal for 6 consecutive 7-d periods. On d 7, blood was collected postprandially every 15 min from -15 to 60 min, 30 to 240 min, 60 to 480 min, and 120 to 720 min. Blood flow was measured simultaneously. Plasma was analyzed for glucose, and net glucose absorption was calculated from plasma portal-arterial differences x plasma flow [blood flow x (1 - hematocrit)]. The specific improvements for long-term use of this model are distal modifications of the catheters, postoperative treatment using parental nutrition and gut motility drug, prevention of infection of body cavity by further tunneling of catheters and blood flow probe cable, and use of ultrasonic blood flow probes and meter. Blood flow measurements using an ultrasonic blood flow probe was not changed after 52 d compared with 10 d post-surgery, indicating the reliability of this model. This catheterized pig model, thus, will allow the long-term study of the kinetics of nutrient absorption.

摘要

本文描述了一种用于研究猪营养物质动力学和定量吸收的改进技术。选用三头体重35千克的雌性猪,通过手术在肝门静脉和颈动脉植入导管,并在门静脉周围安装超声血流探头。导管末端采用特殊设计(环形和孔状)并使用不可吸收缝线,以确保导管位置固定且通畅。导管和血流探头电缆引出体外后,经皮下隧道埋入,以进一步保护。通过避免对内脏的过度操作和干燥,使体腔内的纤维化和粘连最小化。在恢复期间,通过静脉输注氨基酸和电解质对猪进行支持治疗,直至恢复正常进食。每天用肝素化盐水(200 IU/L)冲洗导管。10天后,连续给猪喂食基于小麦和豆粕的日粮,共6个7天周期。在第7天,分别于餐后-15至60分钟、30至240分钟、60至480分钟和120至720分钟,每隔15分钟采集一次血液样本,并同时测量血流。分析血浆中的葡萄糖含量,并根据门静脉-动脉血浆葡萄糖差值×血浆流量[血流×(1-血细胞比容)]计算葡萄糖净吸收量。该模型长期使用的具体改进措施包括导管末端的特殊设计、术后采用肠外营养和胃肠动力药物治疗、通过进一步皮下隧道埋入导管和血流探头电缆预防体腔感染,以及使用超声血流探头和测量仪。术后52天与术后10天相比,使用超声血流探头测量的血流未发生变化,表明该模型具有可靠性。因此,这种导管植入猪模型将有助于长期研究营养物质吸收的动力学。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验