Suppr超能文献

在输注白细胞滤除、ABO血型相同血液制品的心室辅助装置接受者中,缺乏显著的新生HLA同种致敏。

Lack of significant de novo HLA allosensitization in ventricular assist device recipients transfused with leukoreduced, ABO identical blood products.

作者信息

Coppage Myra, Baker Marc, Fialkow Lawrence, Meehan Danielle, Gettings Kelly, Chen Leway, Massey H Todd, Blumberg Neil

机构信息

Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Strong Memorial Hospital, Rochester, NY, USA.

出版信息

Hum Immunol. 2009 Jun;70(6):413-6. doi: 10.1016/j.humimm.2009.03.001. Epub 2009 Mar 9.

Abstract

Ventricular assist devices provide support for a failing heart and often serve as a bridge to transplantation. The use of these devices has also been associated with allosensitization to HLA antigens because of transfusion of blood products. Our program established a protocol mandating the use of leukoreduced, irradiated and ABO identical products, including platelets, in patients receiving initial implantations of VADs as a bridge to transplantation. Recipients were tested for anti-HLA antibodies before VAD implantation and monthly post-implantation by cytotoxicity and solid phase assays. We observed minimal de novo anti-HLA sensitization (<10%) in this population of 55 patients, each receiving a mean of 90 blood components, using this approach. No patient developed broad sensitization (PRA>50%). In conclusion, The use of leukoreduced, irradiated, ABO identical blood products abrogates broad allosensitization in this highly transfused population.

摘要

心室辅助装置为衰竭心脏提供支持,常作为移植的桥梁。由于输血制品,这些装置的使用也与对HLA抗原的同种致敏相关。我们的项目制定了一项方案,要求在接受初次植入心室辅助装置作为移植桥梁的患者中使用白细胞滤除、辐照且ABO血型相同的制品,包括血小板。在心室辅助装置植入前及植入后每月通过细胞毒性和固相检测法对受者进行抗HLA抗体检测。采用这种方法,我们在这55例患者群体中观察到极低的新发抗HLA致敏情况(<10%),每位患者平均接受90份血液成分。没有患者出现广泛致敏(PRA>50%)。总之,在这个大量输血的群体中,使用白细胞滤除、辐照、ABO血型相同的血液制品可消除广泛的同种致敏。

相似文献

3
HLA and MICA allosensitization patterns among patients supported by ventricular assist devices.
J Heart Lung Transplant. 2013 Dec;32(12):1241-8. doi: 10.1016/j.healun.2013.08.014. Epub 2013 Sep 24.
4
Avoidance of cellular blood product transfusions in LVAD recipients does not prevent HLA allosensitization.
J Heart Lung Transplant. 1999 Feb;18(2):160-5. doi: 10.1016/s1053-2498(98)00006-0.
7
Neither pre-transplant rituximab nor splenectomy affects de novo HLA antibody production after renal transplantation.
Kidney Int. 2014 Feb;85(2):425-30. doi: 10.1038/ki.2013.291. Epub 2013 Aug 14.
8
Characterization of ventricular assist device-mediated sensitization in the bridge-to-heart-transplantation patient.
J Thorac Cardiovasc Surg. 2015 Apr;149(4):1161-6. doi: 10.1016/j.jtcvs.2015.01.003. Epub 2015 Jan 8.
10
Transfusion-related immunomodulation: gamma irradiation alters the effects of leukoreduction on alloimmunization.
Transfusion. 2019 Nov;59(11):3396-3404. doi: 10.1111/trf.15555. Epub 2019 Oct 13.

引用本文的文献

1
Leucoreduction of blood components: an effective way to increase blood safety?
Blood Transfus. 2016 May;14(2):214-27. doi: 10.2450/2015.0154-15. Epub 2015 Dec 16.
3
Alternative blood products and clinical needs in transfusion medicine.
Stem Cells Int. 2012;2012:639561. doi: 10.1155/2012/639561. Epub 2012 Apr 8.

本文引用的文献

1
Association of device surface and biomaterials with immunologic sensitization after mechanical support.
J Thorac Cardiovasc Surg. 2008 Jun;135(6):1372-9. doi: 10.1016/j.jtcvs.2007.11.049.
2
Release of biologically active CD154 during collection and storage of platelet concentrates prepared for transfusion.
J Thromb Haemost. 2007 Apr;5(4):788-96. doi: 10.1111/j.1538-7836.2007.02412.x.
3
An association of soluble CD40 ligand (CD154) with adverse reactions to platelet transfusions.
Transfusion. 2006 Oct;46(10):1813-21. doi: 10.1111/j.1537-2995.2006.00979.x.
4
Sensitization following LVAD implantation using leucodepleted blood is not due to HLA antibodies.
Am J Transplant. 2006 Jul;6(7):1712-7. doi: 10.1111/j.1600-6143.2006.01342.x.
6
Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances).
Curr Opin Cardiol. 2006 Mar;21(2):120-6. doi: 10.1097/01.hco.0000210308.64360.8d.
7
Lack of sensitization and equivalent post-transplant outcomes with the Novacor left ventricular assist device.
J Heart Lung Transplant. 2005 Nov;24(11):1886-90. doi: 10.1016/j.healun.2005.03.010. Epub 2005 Aug 8.
8
An overview of approved and investigational left ventricular assist devices.
Proc (Bayl Univ Med Cent). 2004 Oct;17(4):407-10. doi: 10.1080/08998280.2004.11928003.
10
Deleterious clinical effects of transfusion immunomodulation: proven beyond a reasonable doubt.
Transfusion. 2005 Aug;45(2 Suppl):33S-39S; discussion 39S-40S. doi: 10.1111/j.1537-2995.2005.00529.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验