Mellström G A, Landersjö L, Boman A S
Department of Occupational Dermatology, National Institute of Occupational Health, Solna, Sweden.
Am Ind Hyg Assoc J. 1991 Aug;52(8):309-14. doi: 10.1080/15298669191364785.
Two permeation test cells of different sizes were used in a study of the permeation of toluene through two neoprene gloves and special neoprene sheet stock. Three flow rates of the collecting medium through the test cells were used to explore to what extent variation in flow rate would affect the breakthrough times and the steady-state permeation rate. The breakthrough time values were not affected to a significant degree by cell size or by increasing the flow rate of the collecting medium from 60 to 120 mL/min. The steady-state permeation rate values were evidently influenced by the flow rate of the collecting medium and by the size and configuration of the test cell.
在一项关于甲苯透过两种氯丁橡胶手套和特殊氯丁橡胶片材的渗透研究中,使用了两个不同尺寸的渗透试验池。通过试验池的收集介质采用了三种流速,以探究流速变化在多大程度上会影响穿透时间和稳态渗透速率。穿透时间值并未受到试验池尺寸的显著影响,也未因将收集介质的流速从60毫升/分钟提高到120毫升/分钟而受到显著影响。稳态渗透速率值显然受到收集介质流速以及试验池尺寸和结构的影响。