Compère Vincent, Legrand J F, Guitard P G, Azougagh K, Baert O, Ouennich A, Fourdrinier V, Frebourg N, Dureuil B
Department of Anesthesia and Intensive Care, Rouen University Hospital, 1 rue de Germont, 76031 Rouen, France.
Anesth Analg. 2009 Apr;108(4):1326-30. doi: 10.1213/ane.0b013e31819673aa.
Bacterial colonization of peripheral nerve catheters is frequent, although infection is relatively rare. With central venous catheters, the tunneling of the catheter into the subcutaneous tissue significantly decreases catheter colonization and catheter-related sepsis. We evaluated the incidence of bacterial colonization in adult patients with tunnelized perineural nerve catheters.
Peripheral nerve catheters placed under sterile conditions for postoperative analgesia were evaluated prospectively. After removal, they were analyzed for colonization. Quantitative culture was used as described by Brun-Buisson for intravascular catheters. The site of insertion was monitored daily for any signs of infection.
Four-hundred-two patients were included in the study during a 2-yr period. The mean duration of peripheral nerve catheters was 48 h (47-50.4). Positive culture occurred in 25 catheters, indicating that the incidence of colonization was 6.22% (3.8-8.5). The microbiological analysis of the catheter tip cultures revealed coagulase-negative staphylococci in 72%. Twenty-two catheters of 25 catheters each had one microorganism, and for three catheters, two microorganisms were identified. No infection was found in any patient.
The incidence of perineural catheter colonization is low with subcutaneous tunneling. Controlled randomized studies are warranted to determine whether this procedure decreases the risk for infection.
周围神经导管的细菌定植很常见,尽管感染相对少见。对于中心静脉导管,将导管置入皮下组织可显著降低导管定植和导管相关败血症的发生率。我们评估了成年患者经皮下隧道置入的周围神经导管细菌定植的发生率。
对在无菌条件下放置用于术后镇痛的周围神经导管进行前瞻性评估。拔除后,分析其是否定植。采用Brun-Buisson描述的血管内导管定量培养方法。每天监测插入部位有无感染迹象。
在2年期间,402例患者纳入本研究。周围神经导管的平均留置时间为48小时(47 - 50.4小时)。25根导管培养结果呈阳性,表明定植发生率为6.22%(3.8 - 8.5%)。导管尖端培养物的微生物分析显示,72%为凝固酶阴性葡萄球菌。25根导管中有22根各有1种微生物,3根导管有2种微生物。未发现任何患者发生感染。
经皮下隧道置入的周围神经导管定植发生率较低。有必要进行对照随机研究以确定该操作是否能降低感染风险。