To develop a method for automatically triggering centric data acquisition during contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA).
The hypothesis of this work is that the blood signal changes during contrast infusion can be estimated by obtaining a projection of the heart during inversion-recovery prepared data acquisition. A validation study was performed on seven healthy volunteers to test this hypothesis. The peak blood signal enhancement detected from the projection was then used to automatically trigger the start of central k-space data acquisition. Simulations were performed to compare the signal-to-noise ratio (SNR) of the proposed self-triggering method with the fixed delay method. Six healthy volunteers were scanned on a 3T MR system using the proposed self-triggered method to test its effectiveness on coronary artery visualization.
Based on the validation study, the self-triggering method provides an accurate representation of the contrast enhancement. Based on the simulations, self-triggering with centric ordering is expected to give a 27% higher SNR than linear ordering with a fixed imaging delay. Self-triggering was successfully used in all volunteers and showed excellent depiction of the major coronary arteries.
The self-triggering method can be used to automatically determine the optimal delay time for central k-space acquisition, for each individual subject, without the need of any extra setup or user interaction.
开发一种在对比增强全心冠状动脉磁共振血管造影(MRA)期间自动触发中心数据采集的方法。
本研究的假设是,在反转恢复准备的数据采集中,通过获取心脏的投影可以估计对比剂注入期间的血液信号变化。对7名健康志愿者进行了一项验证研究以检验该假设。然后,从投影中检测到的血液信号增强峰值用于自动触发中心k空间数据采集的开始。进行了模拟,以比较所提出的自触发方法与固定延迟方法的信噪比(SNR)。使用所提出的自触发方法在3T MR系统上对6名健康志愿者进行扫描,以测试其在冠状动脉可视化方面的有效性。
基于验证研究,自触发方法能够准确呈现对比增强情况。基于模拟,与具有固定成像延迟的线性排序相比,采用中心排序的自触发预计可使信噪比提高27%。自触发在所有志愿者中均成功应用,并且对主要冠状动脉显示良好。
自触发方法可用于为每个个体自动确定中心k空间采集的最佳延迟时间,无需任何额外设置或用户交互。