Swenson Jana M, Brasso William B, Ferraro Mary Jane, Hardy Dwight J, Knapp Cynthia C, Lonsway David, McAllister Sigrid, Reller L Barth, Sader Helio S, Shortridge Dee, Skov Robert, Weinstein Melvin P, Zimmer Barbara L, Patel Jean B
Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia 30333, USA.
J Clin Microbiol. 2009 Jun;47(6):1902-5. doi: 10.1128/JCM.02304-08. Epub 2009 Apr 8.
This report describes the results of an 11-laboratory study to determine if a cefoxitin broth microdilution MIC test could predict the presence of mecA in staphylococci. Using breakpoints of < or = 4 microg/ml for mecA-negative and > or = 6 or 8 microg/ml for mecA-positive isolates, sensitivity and specificity based on mecA or presumed mecA for Staphylococcus aureus at 18 h of incubation were 99.7 to 100% in three cation-adjusted Mueller-Hinton broths tested. For coagulase-negative strains at 24 h of incubation, breakpoints of < or = 2 microg/ml for mecA-negative and > or = 4 microg/ml for mecA-positive isolates gave sensitivity and specificity of 94 to 99% and 69 to 80%, respectively.
本报告描述了一项由11个实验室参与的研究结果,该研究旨在确定头孢西丁肉汤微量稀释法的最低抑菌浓度(MIC)测试能否预测葡萄球菌中mecA基因的存在情况。对于mecA基因阴性菌株,设定的断点为≤4微克/毫升;对于mecA基因阳性菌株,断点为≥6或8微克/毫升。在所测试的三种阳离子调节的穆勒-欣顿肉汤中,孵育18小时时,基于金黄色葡萄球菌的mecA基因或假定的mecA基因,敏感性和特异性为99.7%至100%。对于凝固酶阴性菌株,孵育24小时时,mecA基因阴性菌株的断点为≤2微克/毫升,mecA基因阳性菌株的断点为≥4微克/毫升,敏感性和特异性分别为94%至99%和69%至80%。