PURPOSE

To determine the pattern of agreement of retinal nerve fiber layer (RNFL) defects between fellow eyes of glaucoma patients measured with optical coherence tomography (OCT).

DESIGN

Observational, cross-sectional study.

METHODS

Seventy-seven glaucoma patients (154 eyes) underwent OCT (Stratus) imaging with the fast RNFL thickness protocol in both eyes. RNFL thickness at each location (12 clock-hour sectors and 4 quadrants) was measured. Main outcome measures were correlations between fellow eyes for RNFL thickness and categorical classifications of RNFL thickness. Nonfellow pairs of eyes, matched randomly, were used as controls.

RESULTS

Fellow eyes showed significant correlations of RNFL thickness in all sectors and quadrants. Categorical ranking also showed significant agreement between fellow eyes in sectors 1 (P < .01) and 7 (P < .03), and in the superior quadrant (P < .01), inferior quadrant (P < .04), and total RNFL thickness (P < .04). None of the paired eyes in the control analysis showed significant correlations.

CONCLUSIONS

The measurement of RNFL thickness and its categorical classification with OCT identified symmetry between fellow eyes of glaucoma patients. Categorical agreement on defective locations was found mostly for the inferior and superior locations, which corresponds with the typical pattern of early glaucomatous damage. Glaucomatous RNFL damage in 1 eye is correlated with damage at corresponding locations of the fellow eye.

摘要

目的

确定采用光学相干断层扫描(OCT)测量的青光眼患者双眼视网膜神经纤维层(RNFL)缺损的一致性模式。

设计

观察性横断面研究。

方法

77例青光眼患者(154只眼)双眼均采用快速RNFL厚度方案进行OCT(Stratus)成像。测量每个位置(12个钟点扇形区和4个象限)的RNFL厚度。主要观察指标为双眼RNFL厚度之间的相关性以及RNFL厚度的分类分级。随机匹配的非双眼作为对照。

结果

双眼在所有扇形区和象限的RNFL厚度均显示出显著相关性。分类分级在扇形区1(P <.01)和7(P <.03)、上象限(P <.01)、下象限(P <.04)以及总RNFL厚度(P <.04)方面也显示出双眼之间的显著一致性。对照分析中的配对眼均未显示出显著相关性。

结论

用OCT测量RNFL厚度及其分类分级可确定青光眼患者双眼之间的对称性。在缺损位置的分类一致性主要见于上、下位置,这与早期青光眼性损害的典型模式相符。一只眼中的青光眼性RNFL损害与对侧眼相应位置的损害相关。