光谱域光学相干断层扫描技术对视网膜神经纤维层的成像:变异性与诊断性能研究

Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study.

作者信息

Leung Christopher Kai-Shun, Cheung Carol Yim-Lui, Weinreb Robert N, Qiu Quanliang, Liu Shu, Li Haitao, Xu Guihua, Fan Ning, Huang Lina, Pang Chi-Pui, Lam Dennis Shun Chiu

机构信息

Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, People's Republic of China.

出版信息

Ophthalmology. 2009 Jul;116(7):1257-63, 1263.e1-2. doi: 10.1016/j.ophtha.2009.04.013. Epub 2009 May 22.

Abstract

OBJECTIVE

To evaluate and compare the retinal nerve fiber layer (RNFL) measurement variability, diagnostic sensitivity and specificity for glaucoma detection, and strength of the structure-function association obtained with a spectral-domain optical coherence tomography (OCT) device (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) and a time-domain OCT device (Stratus OCT; Carl Zeiss Meditec, Inc.).

DESIGN

Prospective, cross-sectional study.

PARTICIPANTS

Ninety-seven normal subjects and 83 glaucoma patients.

METHODS

One eye from each subject was imaged with Cirrus HD-OCT and Stratus OCT. Sixteen and 31 normal eyes were selected randomly to evaluate intravisit repeatability and intervisit reproducibility, respectively. The agreement of RNFL measurements was evaluated with Bland-Altman plots. The diagnostic sensitivity and specificity was examined with the area under the receiver operating characteristic curve (AUC). The association between average RNFL thickness and visual field sensitivity was evaluated with a second-order regression model.

MAIN OUTCOME MEASURES

Retinal nerve fiber layer measurement variability, AUC, and coefficient of determination (R(2)).

RESULTS

The intravisit repeatability of Cirrus HD-OCT ranged between 5.12 and 15.02 mum, and the intervisit reproducibility ranged between 4.31 and 22.01 mum. The intervisit variabilities of sectoral and average RNFL thicknesses were lower in Cirrus HD-OCT compared with Stratus OCT with significant differences at 1, 3, 4, and 8 to 11 o'clock (P< or =0.021). There were proportional biases of RNFL measurements between the 2 OCT devices. The difference of RNFL thicknesses increased with the means. The average (AUC, 0.962 for Cirrus HD-OCT and 0.956 Stratus OCT), superior (AUC, 0.963 and 0.950, respectively), and inferior (AUC, 0.949 and 0.931, respectively) RNFL thicknesses demonstrated the greatest AUCs in both OCT devices with no significant difference detected between the respective measurements (P> or =0.120). The strength of the structure-function association was comparable between Cirrus HD-OCT (R(2) = 0.580) and Stratus OCT devices (R(2) = 0.623; P = 0.918).

CONCLUSIONS

Although the diagnostic performance and the strength of the structure-function association were comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements, Cirrus HD-OCT demonstrated lower measurement variability compared with Stratus OCT with significant differences at 1, 3, 4, and 8 to 11 o'clock. The poor agreement was likely related to the different inherent characteristics of the 2 OCT systems.

摘要

目的

评估并比较使用谱域光学相干断层扫描(OCT)设备(Cirrus HD - OCT;卡尔蔡司医疗技术公司,加利福尼亚州都柏林)和时域OCT设备(Stratus OCT;卡尔蔡司医疗技术公司)测量视网膜神经纤维层(RNFL)的变异性、青光眼检测的诊断敏感性和特异性,以及所获得的结构 - 功能关联强度。

设计

前瞻性横断面研究。

参与者

97名正常受试者和83名青光眼患者。

方法

使用Cirrus HD - OCT和Stratus OCT对每个受试者的一只眼睛进行成像。分别随机选择16只和31只正常眼睛评估单次就诊内的重复性和多次就诊间的可重复性。使用Bland - Altman图评估RNFL测量的一致性。通过受试者操作特征曲线(AUC)下的面积检查诊断敏感性和特异性。使用二阶回归模型评估平均RNFL厚度与视野敏感度之间的关联。

主要观察指标

视网膜神经纤维层测量变异性、AUC和决定系数(R²)。

结果

Cirrus HD - OCT单次就诊内的重复性在5.12至15.02μm之间,多次就诊间的可重复性在4.31至22.01μm之间。与Stratus OCT相比,Cirrus HD - OCT中扇形和平均RNFL厚度的多次就诊间变异性较低,在1点、3点、4点以及8点至11点处存在显著差异(P≤0.021)。两种OCT设备之间的RNFL测量存在比例偏差。RNFL厚度差异随平均值增加。平均(Cirrus HD - OCT的AUC为0.962,Stratus OCT的AUC为0.956)、上方(分别为AUC为0.963和0.950)和下方(分别为AUC为0.949和0.931)RNFL厚度在两种OCT设备中均显示出最大的AUC,各自测量之间未检测到显著差异(P≥0.120)。Cirrus HD - OCT(R² = 0.580)和Stratus OCT设备(R² = 0.623;P = 0.918)之间的结构 - 功能关联强度相当。

结论

尽管Cirrus HD - OCT和Stratus OCT的RNFL测量在诊断性能和结构 - 功能关联强度方面相当,但与Stratus OCT相比,Cirrus HD - OCT显示出较低的测量变异性,在1点、3点、4点以及8点至11点处存在显著差异。一致性较差可能与两种OCT系统的不同固有特性有关。