Eur J Radiol. 2010 Jun;74(3):e29-32. doi: 10.1016/j.ejrad.2009.03.020. Epub 2009 Apr 25.
To describe an ultrasound guided technique of shoulder joint injection at the rotator interval space, using an endocavitary transducer and performed by a radiologist with no previous experience with arthrography.
Accuracy of the intra-articular puncture and incidence of complications were evaluated in 180 consecutive patients submitted to joint puncture for shoulder MR arthrography.
Puncture was accomplished successfully in all cases, of which 92% with one attempt, and 8% with two, both well tolerated by patients. No relevant complications were reported after the procedure.
This study has shown that puncture of the glenohumeral joint guided by ultrasound at the rotator interval space using an endocavitary transducer is easy and quick, even when performed by radiologists with no experience in arthrographic procedures.
描述一种使用腔内探头在肩袖间隙进行关节内注射的超声引导技术,由没有关节造影经验的放射科医生进行。
对 180 例连续接受关节穿刺行肩关节磁共振关节造影的患者,评估关节内穿刺的准确性和并发症的发生率。
所有患者均成功进行了穿刺,其中 92%的患者一次穿刺成功,8%的患者两次穿刺成功,患者均能很好地耐受。操作后无相关并发症报告。
本研究表明,使用腔内探头在肩袖间隙行超声引导下的肩关节穿刺操作简单、快速,即使由没有关节造影经验的放射科医生进行也如此。