Suppr超能文献

使用光学频域成像技术对人眼视网膜在845纳米和1060纳米处的光学特性进行三维逐点比较。

Three-dimensional pointwise comparison of human retinal optical property at 845 and 1060 nm using optical frequency domain imaging.

作者信息

Chen Yueli, Burnes Daina L, de Bruin Martijn, Mujat Mircea, de Boer Johannes F

机构信息

Massachusetts General Hospital, Wellman Center for Photomedicine, 40 Blossom Street, Boston, Massachusetts 02114, USA.

出版信息

J Biomed Opt. 2009 Mar-Apr;14(2):024016. doi: 10.1117/1.3119103.

Abstract

To compare the optical properties of the human retina, 3-D volumetric images of the same eye are acquired with two nearly identical optical coherence tomography (OCT) systems at center wavelengths of 845 and 1060 nm using optical frequency domain imaging (OFDI). To characterize the contrast of individual tissue layers in the retina at these two wavelengths, the 3-D volumetric data sets are carefully spatially matched. The relative scattering intensities from different layers such as the nerve fiber, photoreceptor, pigment epithelium, and choroid are measured and a quantitative comparison is presented. OCT retinal imaging at 1060 nm is found to have a significantly better depth penetration but a reduced contrast between the retinal nerve fiber, the ganglion cell, and the inner plexiform layers compared to the OCT retinal imaging at 845 nm.

摘要

为了比较人视网膜的光学特性,使用光学频域成像(OFDI),在中心波长分别为845纳米和1060纳米的情况下,用两个几乎相同的光学相干断层扫描(OCT)系统采集同一只眼睛的三维体积图像。为了表征视网膜中各个组织层在这两个波长下的对比度,对三维体积数据集进行了仔细的空间匹配。测量了来自不同层(如神经纤维、光感受器、色素上皮和脉络膜)的相对散射强度,并进行了定量比较。研究发现,与845纳米的OCT视网膜成像相比,1060纳米的OCT视网膜成像具有显著更好的深度穿透能力,但视网膜神经纤维、神经节细胞和内网状层之间的对比度有所降低。