Abstract

The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction) x 32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI(vol) of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

摘要

作者通过当前的CT技术开发了一种实验性的细间距探测器多层CT扫描仪,该扫描仪配备了超小焦点X射线管和高密度矩阵探测器。X射线管焦点的横向尺寸为0.4毫米。探测器尺寸为1824通道(方位角方向)×32排(纵向方向),排宽为0.3125毫米,其中较薄的反射分隔器围绕每个探测器单元,并与大面积有源区光电二极管相连。它们被安装在商用64层CT扫描仪机架上,同时可以保持扫描视野(50厘米)和机架旋转速度(0.35秒)。使用丙烯酸狭缝体模时,该实验性CT扫描仪的空间分辨率为0.21 - 0.22毫米(23.8 - 22.7线对/厘米),平面内50%调制传递函数为9.0线对/厘米,10%调制传递函数为22.0线对/厘米。在纵向方向上,使用CATPHAN体模的高分辨率插件时,其空间分辨率为0.24毫米,切片灵敏度曲线半高宽处为0.34毫米。在低对比度可探测性方面,在CTDI(vol)为47.2毫戈瑞时,可以看到0.3%浓度下3毫米的物体。扫描了两种直径为2.75毫米、带有25%、50%和75%阶梯状支架内狭窄的血管体模,重建图像能够清晰分辨每种情况下的狭窄。该实验性CT扫描仪在保持低对比度可探测性的同时提供高分辨率成像,显示出在需要高空间分辨率的临床应用(如内耳、肺部和骨骼成像)或低对比度可探测性(如冠状动脉成像)方面的应用潜力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验