Suppr超能文献

Pressor responses to isometric biting are evoked by somatosensory receptors in periodontal tissue in humans.

作者信息

Okada Yoshiyuki, Kamijo Yoshi-ichiro, Okazaki Kazunobu, Masuki Shizue, Goto Masaki, Nose Hiroshi

机构信息

Department of Sports Medical Sciences, Institute on Aging and Adaptation, Shinshu University Graduate School of Medicine, Asahi 3-1-1, Matsumoto 390-8621, Japan.

出版信息

J Appl Physiol (1985). 2009 Aug;107(2):531-9. doi: 10.1152/japplphysiol.91199.2008. Epub 2009 May 28.

Abstract

Jaw muscle contraction, such as mastication and biting (BT), is known to evoke pressor responses. We examined whether the responses were evoked by somatosensory receptors in periodontal tissue and, moreover, whether they were accompanied by altered arterial baroreflex sensitivity. In the first experiment, we measured mean arterial pressure, heart rate, and muscle sympathetic nerve activity from the peroneal nerve during 2-min isometric BT at 50% maximal voluntary contraction before [control (CNT)] and after pharmacological alveolar nerve block (BLK) in eight young men, while monitoring finger cutaneous vascular conductance, gingival vascular conductance (GVC), surface electromyogram of masseter muscle, and BT force. In the second experiment, cardiac and sympathetic baroreflex sensitivities were successfully determined in eight and five of the subjects, respectively, by the modified Oxford method during 5-min BT at 30% maximal voluntary contraction and also during resting without BT in CNT and BLK, respectively. In the first experiment, although BT in CNT and BLK significantly increased mean arterial pressure, heart rate, and total muscle sympathetic nerve activity (burst amplitude x burst incidence), and decreased finger cutaneous vascular conductance and GVC (P<0.05), all changes except GVC were markedly attenuated in BLK (P<0.05). There were no significant differences in integrated electromyogram and BT force among any trials. In the second experiment, although BT in CNT significantly decreased cardiac and sympathetic baroreflex sensitivities (both, P<0.05), these changes disappeared in BLK. These results suggest that somatosensory receptors in periodontal tissue were involved in pressor responses to isometric BT, which was accompanied by decreased arterial baroreflex sensitivity.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验