Suppr超能文献

[使用FMC培养基和IBG系统读数仪在微孔板上自动读取ABO和Rh血型]

[Automatic reading of ABO and Rh groups on microplates using FMC medium and an IBG Systems reader].

作者信息

Mauri J, Maymo R M, Pérez M A, Yusta V, Mas J, Puig L

机构信息

Banco de Sangre de la Creu Roja de Barcelona.

出版信息

Sangre (Barc). 1991 Jun;36(3):243-7.

PMID:1948546
Abstract

We present in this paper our experience in the routine use of an automatic reader for microtiter plates (IBG Systems). A total of 2044 samples from blood donors have been tested for ABO (haematic and seric) and Rh (D antigen) blood group typing. The red blood cell samples have been tested against monoclonal anti-A, anti-B, anti-AB and anti-Rh 1 (D) sera (using two different anti-D reagents). As a negative control, 3% albumin solution was employed. In order to determine the seric groups, the plasma samples were tested against A1, A2, B and 0 cells. In all cases the red cells were suspended in Ficoll 400R-Methyl cellulose (FMC), and 0.01 Bromelin was added to red blood cell samples to be typed. The obstacles in the automatic readings were mainly solved by visual reading of the microplates. In the 2,044 samples analysed with the automatic reader, 19 discrepancies (0.94%) were found in ABO typing. In all cases the error was in the seric blood group. Three false positive reactions were found with 0 red cells. Two false negative with B red cells, interpreted by the automatic reader as doubtful results. Three positive readings were detected, in one case the positivity was due to alloantibodies (C + D specificities), the other two cases were autoagglutinations. False negative reactions were found, in 11 cases, 8 of them due to lipaemia and the remaining three were haemolysed plasma samples. It should be stressed that out of 19 cases of discrepancy, only 5 (0.24%) were due to the automatic reader while the remaining were due, to sample troubles.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

我们在本文中介绍了我们在常规使用酶标板自动读数仪(IBG系统)方面的经验。对总共2044份献血者样本进行了ABO(血型和血清型)及Rh(D抗原)血型分型检测。红细胞样本用单克隆抗A、抗B、抗AB和抗Rh 1(D)血清进行检测(使用两种不同的抗D试剂)。作为阴性对照,采用3%白蛋白溶液。为了确定血清型,血浆样本用A1、A2、B和O细胞进行检测。在所有情况下,红细胞都悬浮在聚蔗糖400R - 甲基纤维素(FMC)中,并且向待分型的红细胞样本中添加0.01的菠萝蛋白酶。自动读数中的障碍主要通过酶标板的目视读数来解决。在用自动读数仪分析的2044个样本中,ABO血型分型发现19处差异(0.94%)。所有情况下,错误都出在血清血型上。发现3例假阳性反应,针对O型红细胞。发现2例假阴性反应,自动读数仪将其解释为可疑结果。检测到3例假阳性读数,其中1例阳性是由于同种抗体(C + D特异性),另外2例是自身凝集。发现了假阴性反应,有11例,其中8例是由于脂血,其余3例是溶血的血浆样本。应该强调的是,在19例差异中,只有5例(0.24%)是由于自动读数仪,其余是由于样本问题。(摘要截短为250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验