• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Automated turbidimetry of rheumatoid factor without heat inactivation of serum.

作者信息

Borque L, Rus A, Ruiz R

机构信息

Laboratorio de Bioquímica, Hospital San Millán, Logroño, Spain.

出版信息

Eur J Clin Chem Clin Biochem. 1991 Aug;29(8):521-7. doi: 10.1515/cclm.1991.29.8.521.

DOI:10.1515/cclm.1991.29.8.521
PMID:1954306
Abstract

We describe an improved turbidimetric procedure for rheumatoid factor measurement in human serum. Heat-aggregated human IgG is used as antigen. Interference produced by the complement component C1q, which required a previous heat pretreatment of sera, is avoided by the addition of the chemical inhibitor, poly(vinyl sulphonic acid). This inhibitor eliminates C1q interference without affecting the attachment of rheumatoid factor to the Fc part of IgG, thus permitting full automation of the assay. After studying the reactivity of different heat-aggregated IgG preparations, we optimized the procedure for preparing the antigen in order to attain maximal reactivity: IgG was heated at 63 degrees C until the absorbance at 340 nm of a 1/10 dilution of the antigen lay between 0.65 and 0.95 absorbance units. The study of antigen stability showed a maximum aggregation two weeks after preparation. The antigen was then stable and could be used in the assay. The standard curve extends from 30 to 500 x 10(3) IU/l. Intra- and inter-assay CV were less than 5.5%. Relative analytical sensitivity and specificity were 98.3% and 95.2%, respectively. The results agreed well with those obtained by the non-improved turbidimetric procedure (r = 0.996) and with nephelometry values on the Behring nephelometer analyser (r = 0.964). The correlation with an enzyme immunoassay was also good (r = 0.923).

摘要

相似文献

1
Automated turbidimetry of rheumatoid factor without heat inactivation of serum.
Eur J Clin Chem Clin Biochem. 1991 Aug;29(8):521-7. doi: 10.1515/cclm.1991.29.8.521.
2
Development and validation of an automated particle-enhanced nephelometric immunoassay method for the measurement of human plasma C1q.
J Clin Lab Anal. 1995;9(5):302-7. doi: 10.1002/jcla.1860090505.
3
Absorbance nephelometry of immune complexes by reaction with anti-IgG after treatment with polyethylene glycol.用聚乙二醇处理后,通过与抗IgG反应对免疫复合物进行吸光度散射比浊法检测。
Clin Chem. 1983 Dec;29(12):2035-9.
4
Improved immunoturbidimetric method for rheumatoid factor testing.
J Clin Pathol. 1993 Nov;46(11):1065-6. doi: 10.1136/jcp.46.11.1065.
5
Rate nephelometric measurement of rheumatoid factor in serum.血清类风湿因子的速率散射比浊法测定
Clin Chem. 1979 Nov;25(11):1909-14.
6
Automated latex nephelometric immunoassay of theophylline in human serum.人血清中茶碱的自动乳胶比浊免疫测定法。
Eur J Clin Chem Clin Biochem. 1992 May;30(5):307-9.
7
[Interference in turbidimetric immunoassay for serum C-reactive protein due to serum protein abnormalities an immune complex and rheumatoid factor].[血清蛋白异常、免疫复合物及类风湿因子对血清C反应蛋白比浊免疫测定的干扰]
Rinsho Byori. 2000 Aug;48(8):752-9.
8
Turbidimetry of rheumatoid factor in serum with a centrifugal analyzer.
Clin Chem. 1986 Jan;32(1 Pt 1):124-9.
9
A simple procedure for assessing the stability of heat-aggregated IgG preparations.
J Immunol Methods. 1981;41(1):75-9. doi: 10.1016/0022-1759(81)90275-1.
10
Automated turbidimetry of serum lipoprotein(a).血清脂蛋白(a)的自动比浊法
Eur J Clin Chem Clin Biochem. 1993 Dec;31(12):869-74.

引用本文的文献

1
Improved immunoturbidimetric method for rheumatoid factor testing.
J Clin Pathol. 1993 Nov;46(11):1065-6. doi: 10.1136/jcp.46.11.1065.