Suppr超能文献

用于唾液中乳酸测定的一次性电化学发光生物传感器。

Disposable electrochemiluminescent biosensor for lactate determination in saliva.

机构信息

Solid Phase Spectrometry Research Group, Department of Analytical Chemistry, Faculty of Sciences, Campus Fuentenueva, University of Granada, Granada, E-18071, Spain.

出版信息

Analyst. 2009 Jul;134(7):1423-32. doi: 10.1039/b821922b. Epub 2009 Apr 22.

Abstract

An electrochemiluminescence-based disposable biosensor for lactate is characterized. The lactate recognition system is based on lactate oxidase (LOx) and the transduction system consists of luminol. All the needed reagents, luminol, LOx, BSA, electrolyte and buffer have been immobilized by a Methocel membrane placed on the working electrode of the screen-printed electrochemical cell. The measurement of the electrochemiluminescence (ECL) is made possible via a photocounting head when 50 microl of sample is placed into the screen-printed cell with a circular container containing the disposable sensing membrane. The compositions of the membrane and reaction conditions have been optimized to obtain adequate sensitivity. The disposable biosensor responds to lactate after 20 s when two 1 s pulses at 0.5 V are applied to obtain the analytical parameter, the ECL initial rate. The linearized double logarithmic dependence for lactate shows a dynamic range from 10(-5) to 5 x 10(-4) M with a detection limit of 5 x 10(-6) M and a sensor-to-sensor repeatability, as relative standard deviation, RSD, of 3.30% at the medium level of the range. The ECL disposable biosensor was applied to the analysis of lactate in human saliva as an alternative procedure for obtaining the lactate level in a non-invasive way. Interferences coming from components of saliva were studied and eliminated in a simple way that was easy to handle. The procedure was validated for use in human saliva, comparing the results against an enzymatic reference procedure. The proposed method is quick, inexpensive, selective and sensitive and uses conventional ECL instrumentation.

摘要

一种基于电致化学发光的乳酸一次性生物传感器的特点。乳酸识别系统基于乳酸氧化酶(LOx),而传感器系统由鲁米诺组成。所有需要的试剂,如鲁米诺、LOx、BSA、电解质和缓冲液都已经被固定在工作电极上的 Methocel 膜上。当将 50 微升样品放入带有一次性感应膜的圆形容器的丝网印刷电池中时,通过光电计数头可以实现电化学发光(ECL)的测量。为了获得足够的灵敏度,已经对膜的组成和反应条件进行了优化。当在 0.5 V 下施加两个 1 s 的脉冲时,一次性生物传感器在 20 s 后对乳酸做出响应,以获得分析参数,即 ECL 初始速率。乳酸的双对数线性依赖性显示出从 10(-5)到 5 x 10(-4) M 的动态范围,检测限为 5 x 10(-6) M,传感器之间的重复性为 3.30%,相对标准偏差(RSD)在该范围内的中值水平。将 ECL 一次性生物传感器应用于人唾液中乳酸的分析,作为以非侵入性方式获得乳酸水平的替代方法。研究了来自唾液成分的干扰,并以易于处理的简单方式进行了消除。该方法已针对人唾液进行了验证,将结果与酶参考方法进行了比较。该方法快速、廉价、选择性好、灵敏度高,并且使用常规的 ECL 仪器。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验