de Bazelaire Cedric, Farges Cecile, Mathieu Olivier, Zagdanski Anne-Marie, Bourrier Pierre, Frija Jacques, de Kerviler Eric
Department of Radiology, Saint Louis Hospital, Paris VII University, 1 Ave. Claude Vellefaux, Paris, 75475 Cedex 10, France.
AJR Am J Roentgenol. 2009 Aug;193(2):W144-8. doi: 10.2214/AJR.08.2125.
We describe a coaxial introducer provided with an additional blunt-tip stylet that allows safe access to difficult-to-reach lymph nodes in the chest, abdomen, and pelvis under CT control.
Once the thoracic, abdominal, or pelvic wall is crossed by the introducer fitted with the sharp-tip stylet, the blunt-tip stylet replaces the sharp stylet for further progression in the fat toward the target. The soft-tip stylet carries a smaller risk of inadvertent perforation displacing vital structures.
我们描述一种配备额外钝头探针的同轴导入器,其可在CT引导下安全进入胸部、腹部和骨盆中难以触及的淋巴结。
一旦装有尖头探针的导入器穿过胸壁、腹壁或盆腔壁,钝头探针将取代尖头探针,以便在脂肪组织中进一步向目标推进。软头探针意外穿孔移位重要结构的风险较小。