Suppr超能文献

深板层巩膜切除术对角膜生物力学和眼内压的影响。

Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy.

机构信息

Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, 28 rue de Charenton, Paris Cedex 12, France.

出版信息

J Glaucoma. 2010 Apr-May;19(4):252-6. doi: 10.1097/IJG.0b013e3181aff419.

Abstract

PURPOSE

To compare preoperative and postoperative measurements of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA) in eyes undergoing deep sclerectomy with collagen implant (DSCI).

PATIENTS AND METHODS

Thirty eyes of 30 glaucomatous patients undergoing deep sclerectomy with collagen implant and 30 eyes of 30 normal subjects were included. Goldmann applanation IOP, central corneal thickness (CCT), and ORA measurements [corneal compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), corneal resistance factor (CRF), and corneal hysteresis (CH)] were taken the day before deep sclerectomy with collagen implant and on days 1, 8, and 30 after surgery. Preoperative CH values were correlated to the number of preoperative medications and to the CCT. Also, the ORA measurements of normal subjects were compared with the preoperative measurements of the glaucomatous patients.

RESULTS

The 30 glaucomatous eyes showed a statistically significant difference between preoperative and day 1 postoperative GAT IOP, ORA IOPcc, IOPg, CRF, and CH measurements. No statistically significant difference was noted when comparing the GAT IOP, ORA IOPcc, IOPg, and CRF measurements between days 1, 8, and 30 after DSCI.On the contrary, CH values were statistically different when comparing days 1, 8, and 30 after DSCI. The 30 normal eyes showed no statistical difference when compared with the preoperative IOPg parameter in the 30 glaucomatous eyes; the mean CRF and the mean CH values were statistically significantly higher than the preoperative values of the glaucomatous group.

CONCLUSIONS

CH statistically increased between preoperative and postoperative day 1 DSCI. On days 8 and 30, the change in CH values was statistically significant.

摘要

目的

比较行深层巩膜切除术联合胶原植入物(DSCI)前后应用 Goldmann 压平眼压计(GAT)和眼反应分析仪(ORA)测量角膜生物力学特性和眼内压(IOP)的结果。

方法

本研究纳入了 30 例(30 只眼)行 DSCI 的青光眼患者和 30 例(30 只眼)正常对照者。分别于术前及术后第 1、8、30 天测量 GAT 的眼压(IOP)、中央角膜厚度(CCT)和 ORA 的测量值[角膜校正眼压(IOPcc)、与 GAT 相关的眼压(IOPg)、角膜阻力因子(CRF)和角膜滞后量(CH)]。分析术前 CH 值与术前用药数量和 CCT 的相关性。另外,将正常对照者的 ORA 测量值与青光眼患者的术前测量值进行比较。

结果

30 只青光眼眼在术前和术后第 1 天的 GAT IOP、ORA IOPcc、IOPg、CRF 和 CH 测量值之间存在统计学差异。在术后第 1、8 和 30 天,GAT IOP、ORA IOPcc、IOPg 和 CRF 测量值之间无统计学差异。相反,在术后第 1、8 和 30 天,CH 值存在统计学差异。与 30 只青光眼眼的术前 IOPg 参数相比,30 只正常眼无统计学差异;平均 CRF 和平均 CH 值明显高于青光眼组的术前值。

结论

CH 值在术前至术后第 1 天的 DSCI 过程中呈统计学增加。在术后第 8 和 30 天,CH 值的变化具有统计学意义。