Department of Clinical Biochemistry, Derriford Hospital, Plymouth PL6 8DH, UK.
Clin Biochem. 2010 Jan;43(1-2):82-8. doi: 10.1016/j.clinbiochem.2009.08.022. Epub 2009 Sep 8.
To report detailed investigations in a case of elevated serum B(12) due to the presence of an IgG-B(12) complex, to determine the prevalence of this phenomenon and to review the literature.
431 samples with elevated B(12) (median 1250 ng/L, range 901-114,480 ng/L) were treated with polyethylene glycol to precipitate immunoglobulin complexes. Samples with >50% of precipitable B(12) (PPB(12)) were further investigated by protein G adsorption, gel filtration chromatography and measurement of B(12) on different analytical platforms.
Median PPB(12) was 22.6%, but in 35 samples (8.1%), median PPB(12) was more than 50%. Investigation of 27 of these samples with protein G-Sepharose confirmed the presence of an IgG-B(12) complex in 24, and in 15 cases, B(12) fell to within the reference range. After treatment of serum with reagents releasing B(12) from binding proteins, immunoreactivity co-eluted with free B(12). Immunoreactivity of the IgG-bound form of B(12) was confirmed using five B(12) assays in common use in the UK.
At least 8% of samples with elevated vitamin B(12) contain an immunoglobulin complexed form of circulating B(12); this possibility should be considered in the interpretation of results.
报道一例因 IgG-B(12)复合物存在而导致血清 B(12)升高的详细调查结果,确定这种现象的发生率,并复习文献。
对 431 例 B(12)升高(中位数 1250ng/L,范围 901-114480ng/L)的样本进行聚乙二醇沉淀免疫球蛋白复合物处理。对 >50%可沉淀 B(12)(PPB(12))的样本进行进一步研究,包括蛋白 G 吸附、凝胶过滤色谱和不同分析平台上的 B(12)测量。
中位数 PPB(12)为 22.6%,但在 35 例(8.1%)样本中,中位数 PPB(12)超过 50%。对其中 27 例样本进行蛋白 G-琼脂糖凝胶的调查证实,24 例存在 IgG-B(12)复合物,且在 15 例中,B(12)降至参考范围内。用从结合蛋白释放 B(12)的试剂处理血清后,免疫反应性与游离 B(12)共洗脱。使用英国常用的五种 B(12)测定法证实了 B(12)的 IgG 结合形式的免疫反应性。
至少 8%的 B(12)升高样本含有循环 B(12)的免疫球蛋白复合物形式;在解释结果时应考虑到这种可能性。