A high-performance liquid chromatographic method that accurately measures glycerol and myo-inositol from plasma and tissue is described. The method incorporates a pre-column derivatization reaction using aqueous extracts with benzoyl chloride as a modifying agent. The benzoylated derivatives are isolated by HPLC using reversed-phase gradient chromatography and quantified via absorbance detection at 231 nm. The benzoylated derivatives of glycerol and myo-inositol are well resolved from other known carbohydrates, internal standard and other contaminants encountered within samples and during incubation. The benzoylation of these analytes reach a maximum between 3.5 and 6 h of incubation and are stable for at least 24 days at 4 degrees C. The limit of quantization (LOQ) of glycerol was equal to 2.5 nmol/ml plasma and 6.4 nmol/g tissue and the LOQ of myo-inositol was 1.8 nmol/ml plasma and 3.6 nmol/g tissue. Incubation of known standards and samples with benzoyl chloride at 40 degrees C for 4 h showed fully benzoylated products as determined by mass spectral analysis. Calibration curves were linear between 2.7 and 174 nmol for glycerol and 1.4-89 nmol for myo-inositol. Comparison of tissue and plasma concentrations of glycerol and myo-inositol found using this method are in good agreement with other reported values using other techniques.
本文描述了一种高效液相色谱法,可准确测量血浆和组织中的甘油和肌醇。该方法采用柱前衍生化反应,以苯甲酰氯作为改性剂对水提取物进行处理。苯甲酰化衍生物通过反相梯度色谱法进行高效液相色谱分离,并在231nm处通过吸光度检测进行定量。甘油和肌醇的苯甲酰化衍生物与样品及孵育过程中遇到的其他已知碳水化合物、内标和其他污染物能够很好地分离。这些分析物的苯甲酰化在孵育3.5至6小时之间达到最大值,并且在4℃下至少24天保持稳定。甘油的定量限(LOQ)为2.5nmol/ml血浆和6.4nmol/g组织,肌醇的LOQ为1.8nmol/ml血浆和3.6nmol/g组织。通过质谱分析确定,已知标准品和样品在40℃下与苯甲酰氯孵育4小时后显示完全苯甲酰化产物。甘油的校准曲线在2.7至174nmol之间呈线性,肌醇的校准曲线在1.4至89nmol之间呈线性。使用该方法测得的组织和血浆中甘油和肌醇浓度与使用其他技术报告的其他值高度一致。