Suppr超能文献

用于悬浮液的光电密度计。

A PHOTOELECTRIC DENSITOMETER FOR USE WITH SUSPENSIONS.

机构信息

Laboratory of General Physiology, Harvard University, Cambridge.

出版信息

J Gen Physiol. 1934 Jan 20;17(3):383-92. doi: 10.1085/jgp.17.3.383.

Abstract

A device for quickly and accurately measuring the population density of a suspension of microorganisms, permitting the preparation of yeast suspensions of known density to within 1 per cent error, was constructed with two Visitron photoelectric cells, a single light of high intensity and a good Wheatstone bridge for balancing the currents from the two photoelectric cells. A large Pyrex milk culture tube holding the suspension is placed in the path of one beam of light coming through a small longitudinal slit and thence to one photocell; a second similar slit directs another beam of light upon the second photocell, thus causing dissimilar currents to flow, the ratio of whose magnitudes may be measured by the bridge resistances. A relation between these currents and the relative light intensities is shown, and the one significant unmeasurable variable (the characteristic constant of a photocell) is practically eliminated by the use of a method of ratios. After careful standardization of technique the apparatus proved more accurate than other methods available for the purpose indicated. In rapid use its accuracy may be put safely at 1 per cent for measuring the densities of cultures of approximately the same age and composed of cells having comparable optical characteristics.

摘要

一种用于快速准确测量微生物悬浮液的种群密度的装置被构建出来,它使用了两个 Visitron 光电管、一个高强度的单一光源和一个良好的惠斯通电桥,以平衡两个光电管的电流。一个装有悬浮液的大型 Pyrex 牛奶培养管被放置在一束光的路径中,该光束通过一个小的纵向狭缝进入一个光电管;第二个类似的狭缝将另一束光引导到第二个光电管,从而导致不同的电流流动,其大小的比值可以通过桥接电阻来测量。显示了这些电流与相对光强度之间的关系,并且通过使用比率方法,实际上消除了一个重要的不可测量变量(光电管的特征常数)。经过仔细的技术标准化,该仪器在用于所指示的目的时被证明比其他可用方法更准确。在快速使用时,其准确性可安全地达到 1%,用于测量具有相似光学特性的近似相同年龄的培养物的密度。

相似文献

1
A PHOTOELECTRIC DENSITOMETER FOR USE WITH SUSPENSIONS.
J Gen Physiol. 1934 Jan 20;17(3):383-92. doi: 10.1085/jgp.17.3.383.
3
Development of a voltage controlled resistor for use in a self-balancing resistance bridge.
Rev Sci Instrum. 2019 Dec 1;90(12):124706. doi: 10.1063/1.5119720.
4
A fiberoptic reflection densitometer with cardiac output calculator.
Pflugers Arch. 1979 Feb 14;379(1):59-69. doi: 10.1007/BF00622906.
5
New turbidimetric device for measuring cell concentrations in thick microbial suspensions.
Appl Microbiol. 1968 Feb;16(2):212-5. doi: 10.1128/am.16.2.212-215.1968.
6
Microfluidic Wheatstone bridge for rapid sample analysis.
Lab Chip. 2011 Dec 21;11(24):4181-6. doi: 10.1039/c1lc20604d. Epub 2011 Oct 27.
8
Photoelectric device for contact-free recording of the diameters of exposed arteries in situ.
Pflugers Arch. 1977 Mar 11;368(1-2):149-52. doi: 10.1007/BF01063468.

引用本文的文献

1
Stories and photographs of William A. Arnold (1904-2001), a pioneer of photosynthesis and a wonderful friend.
Photosynth Res. 2014 Oct;122(1):87-95. doi: 10.1007/s11120-014-0013-9. Epub 2014 May 27.
2
Experiments.
Photosynth Res. 1991 Feb;27(2):73-82. doi: 10.1007/BF00033247.

本文引用的文献

2
A Photoelectric Nephelometer for Estimating the Population Density of Microörganisms.
J Bacteriol. 1933 Oct;26(4):385-91. doi: 10.1128/jb.26.4.385-391.1933.