前房和玻璃体腔眼压的同步测量。

Simultaneous measurement of intraocular pressure in the anterior chamber and the vitreous cavity.

机构信息

Vissum Corporation, Madrid, Spain.

出版信息

Acta Ophthalmol. 2010 Nov;88(7):e265-8. doi: 10.1111/j.1755-3768.2009.01751.x.

Abstract

PURPOSE

To simultaneously measure, using manometry, the changes of intraocular pressure (IOP) in the anterior chamber and in the vitreous cavity of a single porcine eye, induced by an external column of water.

METHODS

We prospectively measured IOP simultaneously in seven freshly enucleated porcine eyes in both the anterior chamber and the vitreous cavity. Measurements were obtained through blood-pressure transducers connected to 21-gauge catheters. A third cannula was inserted into the anterior chamber to increase the IOP; when the cannula was connected to the water column, the pressure increased rapidly from 0 to 180 mmHg. Changes were registered every 5 seconds during the first minute. Statistical analysis was performed using the Wilcoxon signed-rank test. P ≤ 0.05 was considered significant.

RESULTS

Before the IOP was increased, the median basal IOP value was 18 mmHg in the anterior chamber and 23 mmHg in the vitreous cavity (P > 0.05). Sixty seconds after the end of the experiment, the median IOP value was 135 mmHg (range 122-145) in the anterior chamber and 55 mmHg (range 16-68) in the vitreous cavity (P < 0.01).

CONCLUSION

Cannulation of the anterior chamber measures the actual IOP; however, the IOP measured by cannulation in the vitreous cavity using the same catheter diameter was different, possibly because of the viscosity of the vitreous. The viscosity of the vitreous probably makes the cannulation method of IOP evaluation in the vitreous cavity inaccurate.

摘要

目的

通过眼压计同时测量单个猪眼前房和玻璃体腔内的眼压变化,由外部水柱引起。

方法

我们前瞻性地测量了 7 只新鲜取出的猪眼的前房和玻璃体腔内的眼压。通过连接到 21 号导管的血压换能器进行测量。第三个套管插入前房以增加眼压;当套管连接到水柱时,压力从 0 迅速增加到 180mmHg。在第 1 分钟内,每 5 秒记录一次变化。使用 Wilcoxon 符号秩检验进行统计分析。P≤0.05 被认为具有统计学意义。

结果

在增加眼压之前,前房的中位基础眼压值为 18mmHg,玻璃体腔的中位基础眼压值为 23mmHg(P>0.05)。实验结束后 60 秒,前房的中位眼压值为 135mmHg(范围 122-145),玻璃体腔的中位眼压值为 55mmHg(范围 16-68)(P<0.01)。

结论

前房套管测量的是实际眼压;然而,使用相同导管直径在玻璃体腔内套管测量的眼压值不同,可能是因为玻璃体的粘性。玻璃体的粘性可能使玻璃体腔内眼压评估的套管测量方法不准确。