Capital Eye Specialists, Wellington, New Zealand.
Invest Ophthalmol Vis Sci. 2010 May;51(5):2313-6. doi: 10.1167/iovs.09-3756. Epub 2009 Nov 11.
To evaluate optic nerve diameter changes in glaucomatous and nonglaucomatous eyes during transient elevation of intraocular pressure (IOP).
This prospective experimental study included 100 subjects: 38 with glaucoma and 62 without glaucoma. Elevation of IOP to an average of 64 mm Hg for less than 30 seconds was induced in one eye of all subjects by means of a modified LASIK suction ring. The optic nerve heads were imaged before and during the elevation.
During IOP elevation, optic disc area and linear disc measurements increased by a small but significant amount (3.89%, P < 0.0001 and 0.96%, P = 0.01, respectively). Distances between retinal landmarks did not change significantly (P = 0.25). A smaller optic disc at baseline (P = 0.004) and increased central corneal thickness (CCT; P = 0.011) were associated with a greater increase in disc area relative to other fundus dimensions during IOP elevation. Disc area increased less in patients with glaucoma (P = 0.015). In a multivariate model including age, glaucoma status, CCT, and baseline disc area, there was a small but significant negative correlation between disc area enlargement and baseline optic disc diameter (P = 0.017).
Transient elevation of IOP in adult eyes resulted in increases in disc area and linear disc dimensions, but not in retinal dimensions. The degree of enlargement appears to be less in patients with glaucoma than without and greater with increased corneal thickness. A multivariate model showed that the amount of disc area increase was inversely proportional to baseline disc area but was not related to glaucoma status or CCT. (ClinicalTrials.gov number, NCT00328835).
评估在眼内压(IOP)短暂升高期间青光眼和非青光眼眼的视神经直径变化。
这项前瞻性实验研究纳入了 100 名受试者:38 名青光眼患者和 62 名非青光眼患者。通过改良的 LASIK 抽吸环使所有受试者的一只眼的 IOP 升高至平均 64mmHg 以下,持续不到 30 秒。在升高前和升高期间对视神经头进行成像。
在 IOP 升高期间,视盘面积和线性视盘测量值均有小但显著的增加(分别为 3.89%,P<0.0001 和 0.96%,P=0.01)。视网膜标志之间的距离无显著变化(P=0.25)。基线时视盘较小(P=0.004)和中央角膜厚度(CCT)增加(P=0.011)与IOP 升高期间视盘面积相对于其他眼底尺寸的增加相关。青光眼患者的视盘面积增加较少(P=0.015)。在包括年龄、青光眼状态、CCT 和基线视盘面积的多变量模型中,视盘面积增大与基线视神经直径呈负相关(P=0.017)。
成人眼内压短暂升高导致视盘面积和线性视盘尺寸增加,但视网膜尺寸不变。青光眼患者的增大程度似乎小于非青光眼患者,而角膜厚度增加则增大。多变量模型显示,视盘面积增加量与基线视盘面积成反比,但与青光眼状态或 CCT 无关。(临床试验.gov 编号,NCT00328835)。