The objective of this study was to investigate the sealing properties of 2 warm vertical compaction techniques (BeeFill 2in1, System B/Obtura II) in comparison with single-cone and cold laterally compacted gutta-percha.
The root canals of single-rooted human teeth were prepared by using Mtwo rotary files and divided into 4 groups (n = 10/group) with respect to the filling technique tested: Group 1, cold laterally compacted gutta-percha + AH-26; Group 2, single-cone tapered Mtwo gutta-percha + AH-26; Group 3, System B/ObturaII + AH-26; Group 4, BeeFill 2in1 + 2seal. The leakage of specimens was measured using a fluid-filtration method after 1 and 2 weeks. The data were analyzed statistically with 2-way repeated measures ANOVA (P = .05).
After 1 week, the System B/Obtura II group showed the greatest amount of leakage(P < .05) compared with the other test groups that had similar levels of fluid conductance(P < .05). By the end of the second week, the BeeFill group yielded the greatest amount of leakage (P < .05). Compared with their 1-week values, the fluid conductance of all test groups decreased significantly (P < .05).
The apical sealing efficiency of System B/Obtura II and BeeFill were inferior to the other obturation techniques after 2-week fluid conductance testing in vitro.
本研究的目的是调查两种热垂直加压技术(BeeFill 2in1、System B/Obtura II)与单锥和冷侧向加压牙胶相比的封闭性能。
使用Mtwo旋转锉预备单根人牙的根管,并根据测试的充填技术分为4组(每组n = 10):第1组,冷侧向加压牙胶+AH-26;第2组,单锥度Mtwo牙胶+AH-26;第3组,System B/ObturaII+AH-26;第4组,BeeFill 2in1+2seal。1周和2周后使用流体过滤法测量标本的渗漏情况。数据采用双向重复测量方差分析进行统计学分析(P = .05)。
1周后,与其他具有相似流体传导水平的测试组相比,System B/Obtura II组显示出最大的渗漏量(P < .05)。到第二周结束时,BeeFill组产生了最大的渗漏量(P < .05)。与它们1周时的值相比,所有测试组的流体传导率均显著降低(P < .05)。
在体外进行2周流体传导测试后,System B/Obtura II和BeeFill的根尖封闭效率低于其他充填技术。