This preliminary study examined the effects of hearing loss and aging on the detection of AV asynchrony in hearing-impaired listeners with cochlear implants. Additionally, the relationship between AV asynchrony detection skills and speech perception was assessed. Individuals with normal-hearing and cochlear implant recipients were asked to make judgments about the synchrony of AV speech. The cochlear implant recipients also completed three speech perception tests, the CUNY, HINT sentences, and the CNC test. No significant differences were observed in the detection of AV asynchronous speech between the normal-hearing listeners and the cochlear implant recipients. Older adults in both groups displayed wider timing windows, over which they identified AV asynchronous speech as being synchronous, than younger adults. For the cochlear implant recipients, no relationship between the size of the temporal asynchrony window and speech perception performance was observed. The findings from this preliminary experiment suggest that aging has a greater effect on the detection of AV asynchronous speech than the use of a cochlear implant. Additionally, the temporal width of the AV asynchrony function was not correlated with speech perception skills for hearing-impaired individuals who use cochlear implants.
本初步研究探讨了听力损失和年龄对人工耳蜗植入者听力损失者感知 AV 时移的影响。此外,还评估了 AV 时移检测技能与言语感知之间的关系。要求正常听力者和人工耳蜗植入者对 AV 语音的同步性做出判断。人工耳蜗植入者还完成了三项言语感知测试,即 CUNY 测试、HINT 句子测试和 CNC 测试。正常听力者和人工耳蜗植入者在检测 AV 异步语音方面没有显著差异。两组中的老年人在他们将 AV 异步语音识别为同步的时间窗口都比年轻人宽。对于人工耳蜗植入者,没有观察到时间异步窗口的大小与言语感知性能之间存在关系。本初步实验的结果表明,年龄对 AV 异步语音的检测影响大于使用人工耳蜗。此外,对于使用人工耳蜗的听力障碍者,AV 时移功能的时间宽度与言语感知技能无关。