PURPOSE

The purpose of this study was to assess the capacity of dental 3-dimensional computed tomography (3D-CT; limited cone-beam CT) to predict the exposure and injury of the inferior alveolar nerve (IAN) after mandibular third molar extractions.

MATERIALS AND METHODS

This study was a retrospective case series of patients who presented for extraction of mandibular third molars. Subjects eligible for study enrollment were those who underwent preoperative dental 3D-CT because the mandibular third molars were determined to be extremely close to the IAN on panoramic radiogram. The predictive variable was the anatomic relation of the IAN and third molar apices and was a binary variable, contact or noncontact. The primary outcome variable was IAN exposure, and the secondary outcome variable was IAN injury.

RESULTS

From January 2006 to August 2007, 1,853 mandibular third molars in 1,539 patients were extracted. Among them, dental 3D-CT was performed on 53 third molars in 47 patients. The mandibular third molars were judged to make contact with the mandibular canal on dental 3D-CT images in 35 cases (66%). Intraoperative IAN exposure was observed in 17 (49%) contact cases and 2 (11%) noncontact cases on dental 3D-CT images. Of 53 cases extracted after dental 3D-CT examinations, IAN injury occurred in 8 cases (15%). IAN exposure led to IAN injury in 36.8% of cases, whereas IAN injury occurred in only 2.9% of cases without IAN exposure. Although the incidence of IAN injury in the molar-canal contact cases was 23%, all 8 cases with IAN injury (100%) were included in these contact cases.

CONCLUSION

When viewing the anatomic relation between the IAN and mandibular third molar root apices using dental 3D-CT, contact of the 2 anatomic structures results in an increased risk for IAN exposure or injury.

摘要

目的

本研究旨在评估牙科三维计算机断层扫描(3D-CT;有限锥形束CT)预测下颌第三磨牙拔除后下牙槽神经(IAN)暴露和损伤的能力。

材料与方法

本研究是对前来拔除下颌第三磨牙的患者进行的回顾性病例系列研究。符合研究纳入标准的受试者是那些因全景X线片显示下颌第三磨牙与IAN极为接近而接受术前牙科3D-CT检查的患者。预测变量是IAN与第三磨牙根尖的解剖关系,为二元变量,即接触或不接触。主要结局变量是IAN暴露,次要结局变量是IAN损伤。

结果

2006年1月至2007年8月,共拔除了1539例患者的1853颗下颌第三磨牙。其中,47例患者的53颗第三磨牙进行了牙科3D-CT检查。在牙科3D-CT图像上,35例(66%)下颌第三磨牙被判定与下颌管接触。在牙科3D-CT图像上,术中观察到17例(49%)接触病例和2例(11%)非接触病例出现IAN暴露。在牙科3D-CT检查后拔除的53例病例中,8例(15%)发生IAN损伤。IAN暴露导致36.8%的病例发生IAN损伤,而在无IAN暴露的病例中,IAN损伤仅发生在2.9%的病例中。尽管磨牙-根管接触病例中IAN损伤的发生率为23%,但所有8例IAN损伤病例(100%)均包含在这些接触病例中。

结论

使用牙科3D-CT观察IAN与下颌第三磨牙根尖之间的解剖关系时,这两个解剖结构的接触会增加IAN暴露或损伤的风险。