To predict the relationship between lower third molars and the inferior alveolar canal (IAC) from panoramic radiographs, and to establish criteria for using computed tomography (CT).
A retrospective cohort study was performed involving 443 patients (695 teeth). Predictor variables were the distance between the third molar and the IAC, and findings according to the Rood's criteria. Outcome variables were the absence of cortication between the third molar and the IAC on the CT image, and injury of the inferior alveolar nerve (IAN). Statistical analysis was performed to assess the relationship between predictor and outcome variables.
All patients had preoperative panoramic radiographs, and 71 patients (119 teeth) also had CT images. On CT examination, 48 teeth (40.3%) showed absence of cortication. Injury of the IAN was reported in 7 cases (1.0%), 5 of which exhibited absence of cortication; the remaining 2 did not have CT scans. Five of the 48 cases showing absence of cortication exhibited IAN injury, and none of the cases with cortication exhibited IAN injury. On the panoramic images, the following signs were strongly correlated with absence of cortication: a superimposed relationship between the third molar and the IAC; darkness of the root; and diversion and narrowing of the IAC.
Presence of Rood's criteria was a predictor for a contact relationship between the third molar and the IAC, and an indication for CT examination. However, a superimposed relationship and the absence of Rood's criteria did not necessarily signify a separate relationship between third molar and the IAC.
通过全景X线片预测下颌第三磨牙与下颌管(IAC)之间的关系,并建立使用计算机断层扫描(CT)的标准。
进行一项回顾性队列研究,纳入443例患者(695颗牙齿)。预测变量为第三磨牙与下颌管之间的距离以及根据Rood标准的检查结果。结局变量为CT图像上第三磨牙与下颌管之间皮质骨缺失情况以及下牙槽神经(IAN)损伤情况。进行统计分析以评估预测变量与结局变量之间的关系。
所有患者术前行全景X线片检查,71例患者(119颗牙齿)还进行了CT检查。CT检查显示,48颗牙齿(40.3%)存在皮质骨缺失。报告有7例(1.0%)IAN损伤,其中5例存在皮质骨缺失;其余2例未行CT扫描。48例皮质骨缺失病例中有5例出现IAN损伤,而皮质骨完整的病例均未出现IAN损伤。在全景图像上,以下征象与皮质骨缺失密切相关:第三磨牙与下颌管重叠关系;牙根密度减低;下颌管移位和变窄。
符合Rood标准是第三磨牙与下颌管存在接触关系的预测指标及CT检查的指征。然而,重叠关系以及不符合Rood标准并不一定意味着第三磨牙与下颌管之间存在分隔关系。