Suppr超能文献

体内骨反应和机械评估使用山羊的髂嵴作为植入模型的电喷 CaP 纳米粒子涂层。

In vivo bone response and mechanical evaluation of electrosprayed CaP nanoparticle coatings using the iliac crest of goats as an implantation model.

机构信息

Department of Biomaterials, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands.

出版信息

Acta Biomater. 2010 Jun;6(6):2227-36. doi: 10.1016/j.actbio.2009.11.030. Epub 2009 Nov 26.

Abstract

Recent trends in clinical implantology include the use of endosseous dental implant surfaces embellished with nano-sized modifications. The current study was initiated to evaluate the mechanical properties, as well as the potential beneficial effects, of electrosprayed CaP nanoparticle-coated (nano-CaP) implants on the in vivo osteogenic response, compared with grit-blasted, acid-etched (GAE) implant surfaces as controls. For this purpose nano-CaP coatings were deposited on cylindrical screw-type (St) implants and implanted bilaterally into the iliac crest of goats for 6weeks. In addition to histological and histomorphometrical analyses, insertion torque and removal torque values were measured on implant placement and retrieval, respectively. The present study showed similar insertion and removal torque values for nano-CaP-coated and GAE control implants, with no statistically significant increase in torque value during the implant period for either group. With regard to bone-implant contact and peri-implant bone volume, no significant differences were found between nano-CaP-coated and GAE implants after 6weeks implantation. In conclusion, this study has demonstrated that in situations in which implants are placed in a non-compromised situation using a standard press fit implantation strategy the performance of electrosprayed nano-CaP coatings is comparable with GAE implants, both with respect to implant fixation and bone healing response.

摘要

近年来,临床种植体学的发展趋势包括使用表面经过纳米级修饰的骨内牙科植入物。本研究旨在评估与喷砂酸蚀(GAE)表面作为对照相比,电喷 CaP 纳米颗粒涂层(nano-CaP)植入物对体内成骨反应的机械性能和潜在有益影响。为此,在圆柱形螺旋型(St)植入物上沉积了纳米 CaP 涂层,并将其双侧植入山羊的髂嵴 6 周。除了组织学和组织形态计量学分析外,还分别在植入和取出时测量了植入物的插入扭矩和取出扭矩值。本研究表明,纳米 CaP 涂层和 GAE 对照植入物的插入和取出扭矩值相似,在植入期间,两组的扭矩值均无统计学显著增加。关于骨-植入物接触和植入物周围骨量,在植入 6 周后,纳米 CaP 涂层和 GAE 植入物之间没有发现显著差异。总之,本研究表明,在使用标准压配合植入策略将植入物植入非受损部位的情况下,电喷纳米 CaP 涂层的性能与 GAE 植入物相当,无论是在植入物固定还是骨愈合反应方面。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验