Components Development Laboratory, NHS Blood and Transplant, Essex, UK.
Transfusion. 2010 May;50(5):970-9. doi: 10.1111/j.1537-2995.2009.02500.x. Epub 2009 Nov 23.
A filter has been developed (P-Capt, MacoPharma) to remove infectious prions from red blood cells (RBCs). We sought to assess 1) its operational use, 2) the quality of filtered components, and 3) whether filtration resulted in any significant changes to blood group antigens.
A total of 272 leukoreduced RBC units, including units processed using "top-and-top" (TAT) and "bottom-and-top" (BAT) methods, were prion reduced using the P-Capt filter. All RBCs were assessed using standard in vitro tests of RBC quality. Changes to blood group antigen expression were also investigated, including the exposure of cryptantigens and the ability of filtered RBCs to be crossmatched.
Ninety-nine percent of TAT units and 58% of BAT units had a hemoglobin (Hb) content of more than 40 g. Hemolysis increased immediately after filtration, but units remained within UK specification throughout storage. Prion reduction resulted in the loss of 7 to 8 g of Hb and reductions in hematocrit of 6% to 9% due to the filter containing 40 mL of saline, adenine, glucose, and mannitol. Other RBC quality data, including extracellular potassium, 2,3-diphosphoglycerate, and adenosine triphosphate were similar to historical control data. There was no evidence of any immunologic changes of clinical relevance to the RBC membrane after filtration.
Prion filtration does not appear to have a detrimental effect on basic in vitro measures of RBC quality or on blood group antigens as assessed by in vitro methods. However, prion filtration using the P-Capt filter results in loss of Hb.
已经开发出一种过滤器(P-Capt,MacoPharma)来从红细胞(RBC)中去除感染性朊病毒。我们旨在评估 1)其操作使用情况,2)过滤成分的质量,以及 3)过滤是否会导致血型抗原发生任何重大变化。
共使用 P-Capt 过滤器对 272 个白细胞减少的 RBC 单位(包括使用“顶-顶”(TAT)和“底-顶”(BAT)方法处理的单位)进行了朊病毒减少处理。所有 RBC 均采用 RBC 质量的标准体外测试进行评估。还研究了血型抗原表达的变化,包括隐匿抗原的暴露以及过滤 RBC 进行交叉配血的能力。
99%的 TAT 单位和 58%的 BAT 单位的血红蛋白(Hb)含量超过 40 g。过滤后立即发生溶血,但整个储存过程中单位均符合英国规范。朊病毒减少导致 7 至 8 g 的 Hb 损失以及 6%至 9%的血细胞比容降低,这是由于过滤器中含有 40 mL 的生理盐水、腺嘌呤、葡萄糖和甘露醇。其他 RBC 质量数据,包括细胞外钾、2,3-二磷酸甘油酸和三磷酸腺苷,与历史对照数据相似。过滤后,RBC 膜没有任何与临床相关的免疫变化证据。
朊病毒过滤似乎不会对 RBC 质量的基本体外测量值或通过体外方法评估的血型抗原产生不利影响。然而,使用 P-Capt 过滤器进行朊病毒过滤会导致 Hb 损失。