Periprosthetic femoral fractures following total hip arthroplasty are getting more prevalent. The aim of this study was to evaluate the clinical results of combined use of uncemented extensively porous coated femoral components with onlay cortical strut allografts in revision of Vancouver type B2 and B3 periprosthetic femoral fractures.
Thirteen hips after total hip arthroplasty in 13 patients who suffered a Vancouver B2 or B3 periprosthetic fracture were treated with an uncemented extensively porous coated femoral component combined with onlay cortical strut allografts. Each patient was assigned a Harris hip score, and a visual analog scale (VAS) score for pain and satisfaction. Radiographs were examined for component stability, fracture site and allograft-host union and allograft reconstruction.
At an average of 5.3-year follow-up, no patient required repeat revision. The average Harris hip score was (71.8 +/- 6.3) points, the pain VAS score was (16.6 +/- 4.3) points, and the patient satisfaction VAS score was (81.5 +/- 5.7) points. Radiographic examination showed no detectable loosening of the prostheses, and 12 cases were presented fixation by osseointegration and the other one was stable fibrous ingrown fixation. All fractures united for (5.2 +/- 1.4) months in average. And all onlay strut allografts united to host bone for about (11.5 +/- 2.6) months.
Combined use of uncemented, long stemmed, extensively porous coated implant with cortical onlay strut allografts can achieve good clinic results and high rate of union for both fracture site and allograft-host bone junction. This technique could be used routinely to augment fixation and healing of Vancouver B2 and B3 periprosthetic fractures.
全髋关节置换术后的股骨假体周围骨折越来越常见。本研究旨在评估非骨水泥广泛多孔涂层股骨假体与骨皮质嵌插式同种异体骨移植在温哥华 B2 和 B3 型股骨假体周围骨折翻修中的临床效果。
对 13 例髋关节置换术后发生温哥华 B2 或 B3 型股骨假体周围骨折的患者,采用非骨水泥广泛多孔涂层股骨假体与骨皮质嵌插式同种异体骨移植进行治疗。每位患者均接受 Harris 髋关节评分、疼痛视觉模拟评分(VAS)和满意度评分。对假体稳定性、骨折部位、移植物与宿主骨的愈合以及移植物重建情况进行 X 线检查。
平均随访 5.3 年,无患者需要再次翻修。平均 Harris 髋关节评分为(71.8±6.3)分,疼痛 VAS 评分为(16.6±4.3)分,患者满意度 VAS 评分为(81.5±5.7)分。X 线检查显示假体无明显松动,12 例为骨整合固定,1 例为稳定的纤维性内植物固定。所有骨折平均愈合时间为(5.2±1.4)个月。所有嵌插式同种异体骨移植平均在宿主骨中愈合时间为(11.5±2.6)个月。
非骨水泥、长柄、广泛多孔涂层假体与皮质嵌插式同种异体骨移植的联合应用可获得良好的临床效果和高的骨折部位和移植物与宿主骨交界处的愈合率。该技术可常规用于增强温哥华 B2 和 B3 型股骨假体周围骨折的固定和愈合。