Department of Radiology, Hokkaido University Graduate School of Medicine, N15, W7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan.
Eur J Radiol. 2011 Jul;79(1):15-20. doi: 10.1016/j.ejrad.2009.11.013. Epub 2009 Dec 5.
To evaluate the speed and precision of split renal volume (SRV) measurement, which is the ratio of unilateral renal volume to bilateral renal volume, using a newly developed software for computed tomographic (CT) volumetry and to investigate the usefulness of SRV for the estimation of split renal function (SRF) in kidney donors.
Both dynamic CT and renal scintigraphy in 28 adult potential living renal donors were the subjects of this study. We calculated SRV using the newly developed volumetric software built into a PACS viewer (n-SRV), and compared it with SRV calculated using a conventional workstation, ZIOSOFT (z-SRV). The correlation with split renal function (SRF) using (99m)Tc-DMSA scintigraphy was also investigated.
The time required for volumetry of bilateral kidneys with the newly developed software (16.7±3.9s) was significantly shorter than that of the workstation (102.6±38.9s, p<0.0001). The results of n-SRV (49.7±4.0%) were highly consistent with those of z-SRV (49.9±3.6%), with a mean discrepancy of 0.12±0.84%. The SRF also agreed well with the n-SRV, with a mean discrepancy of 0.25±1.65%. The dominant side determined by SRF and n-SRV showed agreement in 26 of 28 cases (92.9%).
The newly developed software for CT volumetry was more rapid than the conventional workstation volumetry and just as accurate, and was suggested to be useful for the estimation of SRF and thus the dominant side in kidney donors.
评估使用新开发的 CT 容积测量软件计算单侧肾体积与双侧肾体积之比的分肾体积(SRV)的速度和精度,并探讨 SRV 在评估活体供肾者分肾功能(SRF)中的作用。
本研究对 28 例成年潜在活体供肾者进行了动态 CT 和肾闪烁显像检查。我们使用内置在 PACS 查看器中的新开发的容积软件(n-SRV)计算 SRV,并与使用常规工作站(ZIOSOFT,z-SRV)计算的 SRV 进行比较。还研究了与(99m)Tc-DMSA 闪烁显像法测量的 SRF 的相关性。
新开发软件双侧肾容积测量所需时间(16.7±3.9s)明显短于工作站(102.6±38.9s,p<0.0001)。n-SRV(49.7±4.0%)的结果与 z-SRV(49.9±3.6%)高度一致,平均差异为 0.12±0.84%。SRF 也与 n-SRV 吻合良好,平均差异为 0.25±1.65%。SRF 和 n-SRV 确定的优势侧在 28 例中有 26 例(92.9%)一致。