在回收式输血过程中,与白细胞去除过滤器相关的急性低血压。

Acute hypotension associated with leucocyte depletion filters during cell salvaged blood transfusion.

机构信息

Queen Alexandra Hospital, Portsmouth, UK.

出版信息

Anaesthesia. 2010 Jul;65(7):742-4. doi: 10.1111/j.1365-2044.2009.06190.x. Epub 2009 Dec 9.

Abstract

Summary Intra-operative cell salvage is used in more than 75% of NHS hospitals in the United Kingdom and is a safe and cost effective alternative to allogenic blood transfusion. We report a case of acute hypotension during reinfusion of cell salvaged blood through a leucocyte depletion filter that occurred during a caesarean section. We review the literature of hypotension associated with the use of bedside leucocyte depletion filters.

摘要

摘要术中细胞回收在英国超过 75%的国民保健服务(NHS)医院使用,是异体输血的一种安全且具有成本效益的替代方法。我们报告了一例在剖腹产过程中通过白细胞滤器再输注细胞回收血时发生急性低血压的病例。我们回顾了与床边白细胞滤器使用相关的低血压文献。