Yeager W M, Lucas R M, Daum K A, Sensintaffar E, Poppell S, Feldt L, Clarkin M
National Air and Radiation Environmental Laboratory, U.S. Environmental Protection Agency, Montgomery, AL 36109.
Health Phys. 1991 Apr;60(4):507-15. doi: 10.1097/00004032-199104000-00004.
Three models of alpha-track detector (ATD) Rn monitors were exposed in Environmental Protection Agency (EPA) Rn chambers to obtain estimates of precision and bias for the National Residential Radon Survey (NRRS). Exposures in this study ranged from 37 to 740 Bq y m-3 (1 to 20 pCi y L-1), plus blanks. These exposures correspond to the range expected in most U.S. residences. All detectors were purchased through a Rn mitigation firm to assure that the vendors did not give special attention to the ATDs used in this study. Ten ATDs of each model were studied at 12 exposures. The mean and standard deviation of the reported values for each model were calculated and compared with the continuously monitored chamber concentrations to determine the bias and precision at each exposure. Results of this analysis were discussed with the vendors, who took corrective actions. Changes in track counting procedures and calibrations improved detector performance. Readings of one detector were adjusted based on a regression of the monitored values on the reported values.