回顾性与前瞻性心电图门控双源 CT 在先天性心脏病患儿中的应用:图像质量和辐射剂量的比较。

Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose.

机构信息

Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center Clinical Research Institute, Seoul National University Hospital, Seoul, Korea.

出版信息

Int J Cardiovasc Imaging. 2010 Feb;26 Suppl 1:63-73. doi: 10.1007/s10554-009-9579-2. Epub 2010 Jan 1.

Abstract

We wanted to compare the image quality and radiation dose of retrospective versus prospective ECG-gated dual-source CT imaging in pediatric patients with congenital heart diseases. We retrospectively evaluated 44 thorax CT images that were obtained using two different protocols (retrospective helical ECG-gated [n = 22] versus prospective non-helical ECG-triggering [n = 22]) in patients younger than 5 years. Two radiologists evaluated the image quality, using a 3- or 4-point scale, in terms of the degree of homogeneity of vascular enhancement, the stair-step artifacts, the subjective image noise and the overall subjective image quality. We compared the mean score of image quality, the frequency of marked stair-step artifact and the estimated radiation dose. The mean score of the homogeneity of vascular enhancement and the stair-step artifacts tended to be higher for the patients in the retrospective group than that for the patients in the prospective group, but this did not reach statistical significance. However, marked stair-step artifacts were significantly more frequent in the prospective scan group than that in the retrospective scan group (25.8 vs. 7.6%, respectively, P < 0.01). The mean scores for subjective image noise and the overall image quality were better in the retrospective group than those scores in the prospective group (P < 0.01). The mean estimated effective dose was higher for the retrospective ECG-gated helical scan than that for the prospective non-helical scan (0.79 vs. 0.21 mSv, respectively, P < 0.01). Retrospective ECG-gated helical dual-source CT using aggressive ECG pulsing can be obtained with an acceptable radiation dose and superior image quality, as compared to the prospective ECG-triggering technique, for the evaluation of congenital heart diseases in pediatric patients who are younger than 5 years old.

摘要

我们旨在比较回顾性与前瞻性心电门控双源 CT 成像在先天性心脏病儿科患者中的图像质量和辐射剂量。我们回顾性评估了 44 例胸部 CT 图像,这些图像是使用两种不同方案(回顾性螺旋心电门控[ n = 22]与前瞻性非螺旋心电触发[ n = 22])在 5 岁以下患者中获得的。两名放射科医生使用 3 分或 4 分制评估了图像质量,从血管增强均匀度、阶梯状伪影、主观图像噪声和整体主观图像质量等方面进行了评估。我们比较了图像质量的平均评分、标记的阶梯状伪影的频率和估计的辐射剂量。回顾性组患者的血管增强均匀度和阶梯状伪影的平均评分倾向于高于前瞻性组患者,但未达到统计学意义。然而,前瞻性扫描组明显有更多的标记阶梯状伪影(分别为 25.8%和 7.6%, P < 0.01)。回顾性组的主观图像噪声和整体图像质量的平均评分优于前瞻性组( P < 0.01)。回顾性心电门控螺旋扫描的平均估计有效剂量高于前瞻性非螺旋扫描(分别为 0.79 毫希弗和 0.21 毫希弗, P < 0.01)。与前瞻性心电触发技术相比,在 5 岁以下先天性心脏病儿科患者的评估中,使用激进心电脉冲的回顾性心电门控螺旋双源 CT 可以获得可接受的辐射剂量和更好的图像质量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验