Abstract

OBJECTIVE

To evaluate clinical value of oxidized lipoprotein(a) [ox-Lp(a)] levels.

DESIGN AND METHODS

Ox-Lp(a) were measured by 2 ELISAs using antibodies against ox-Lp(a) [ox-Lp(a)1] or oxidized low-density lipoprotein [ox-Lp(a)2], and studied in 161 acute coronary syndromes (ACS) patients, 114 stable coronary artery disease (CAD) and 100 control subjects.

RESULTS

Ox-Lp(a)1 was found related with ox-Lp(a)2 (r=0.864, P=0.000). Controlling for plasma lipids, Lp(a) and clinical characteristics, odds ratios of ox-Lp(a)1 on ACS and stable CAD were 5.06 (95% confidence interval 1.82-14.04) and 2.20 (0.78-6.22); those of ox-Lp(a)2 were 3.37 (1.07-10.63) and 1.35 (0.41-4.48), respectively. Receiver-operating characteristic curve analysis confirmed that performances of ox-Lp(a)1 were significantly superior to those for ox-Lp(a)2 in ACS (area: 0.803 vs. 0.723, P<0.001) and stable CAD (area: 0.670 vs. 0.607, P<0.01).

CONCLUSION

Ox-Lp(a) levels using antibodies against ox-Lp(a) may represent a better risk marker than those using antibodies against oxidized low-density lipoprotein for ACS and stable CAD.

摘要

目的

评估氧化脂蛋白(a) [ox-Lp(a)]水平的临床价值。

设计和方法

使用针对 ox-Lp(a) [ox-Lp(a)1]或氧化型低密度脂蛋白 [ox-Lp(a)2]的 2 种 ELISA 法测量 ox-Lp(a),并在 161 例急性冠脉综合征 (ACS)患者、114 例稳定型冠心病 (CAD)患者和 100 例对照者中进行研究。

结果

发现 ox-Lp(a)1 与 ox-Lp(a)2 相关 (r=0.864,P=0.000)。在校正血浆脂质、Lp(a)和临床特征后,ox-Lp(a)1 对 ACS 和稳定型 CAD 的比值比分别为 5.06 (95%置信区间 1.82-14.04)和 2.20 (0.78-6.22);ox-Lp(a)2 的比值比分别为 3.37 (1.07-10.63)和 1.35 (0.41-4.48)。受试者工作特征曲线分析证实,ox-Lp(a)1 在 ACS (曲线下面积:0.803 比 0.723,P<0.001)和稳定型 CAD (曲线下面积:0.670 比 0.607,P<0.01)中的性能明显优于 ox-Lp(a)2。

结论

针对 ox-Lp(a)的抗体检测 ox-Lp(a)水平可能比针对氧化型低密度脂蛋白的抗体检测 ox-Lp(a)水平更能作为 ACS 和稳定型 CAD 的更好风险标志物。