Abstract

Three different types of implantable cardiac devices are now commonly used in clinical medicine: pacemakers (including cardiac resynchronization systems), cardiac defibrillators, and loop recorders. Although pacing specialists and electrophysiologists have traditionally been responsible for device follow-up, the newest generation of implanted devices stores a wealth of information that can be useful to the clinical cardiologist. Important information, in addition to device function, such as incidence and type of arrhythmias, general clinical condition of the patient, and hemodynamic status can now be stored on large databases that are available via web access to all physicians caring for an individual patient. The advent of the remote monitoring capability of implanted devices has initiated a rapidly accelerating paradigm shift in device follow-up that can potentially improve patient care at lower cost.

摘要

目前,临床上常用的植入式心脏设备主要有三种:心脏起搏器(包括心脏再同步治疗系统)、心脏除颤器和植入式循环记录仪。尽管起搏专家和电生理学家一直负责设备随访,但新一代植入式设备可存储大量对临床心内科医生有用的信息。除了设备功能(如心律失常的发生和类型、患者一般临床情况和血流动力学状态)外,还可以将重要信息存储在通过网络可访问的大型数据库中,以便为每位患者提供治疗的医生使用。植入式设备远程监测功能的出现,引发了设备随访模式的快速转变,这可能会降低成本,提高患者的护理质量。

相似文献

1
Remote monitoring of patients with implanted cardiac devices.
Clin Cardiol. 2010 Jan;33(1):10-7. doi: 10.1002/clc.20688.
4
Remote monitoring for implantable cardiac electronic devices.
Heart Lung Circ. 2012 Jun;21(6-7):352-7. doi: 10.1016/j.hlc.2012.03.007. Epub 2012 Apr 18.
5
[Active cardiac implantable electronic devices: What is possible in ambulatory health care in 2017?].
Herzschrittmacherther Elektrophysiol. 2017 Sep;28(3):279-286. doi: 10.1007/s00399-017-0524-0. Epub 2017 Aug 22.
6
ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).
Ann Noninvasive Electrocardiol. 2012 Jan;17(1):36-56. doi: 10.1111/j.1542-474X.2011.00484.x.
7
Home Monitoring for Cardiovascular Implantable Electronic Devices: Benefits to Patients and to Their Follow-up Clinic.
AACN Adv Crit Care. 2015 Oct-Dec;26(4):343-55. doi: 10.1097/NCI.0000000000000110.
8
Remote monitoring of cardiac implantable electronic devices (CIED).
Trends Cardiovasc Med. 2016 Aug;26(6):568-77. doi: 10.1016/j.tcm.2016.03.012. Epub 2016 Mar 31.
9
Remote-only monitoring for patients with cardiac implantable electronic devices: a before-and-after pilot study.
CMAJ Open. 2021 Jan 25;9(1):E53-E61. doi: 10.9778/cmajo.20200041. Print 2021 Jan-Mar.
10

引用本文的文献

1
Connected to the cloud at time of death: a case report.
J Med Case Rep. 2024 Aug 3;18(1):360. doi: 10.1186/s13256-024-04573-5.
2
"Digital biomarkers" in preclinical heart failure models - a further step towards improved translational research.
Heart Fail Rev. 2023 Jan;28(1):249-260. doi: 10.1007/s10741-022-10264-4. Epub 2022 Aug 24.
3
"We as Human Beings Get Farther and Farther Apart": the experiences of patients with remote monitoring systems.
Heart Lung. 2013 Sep-Oct;42(5):313-9. doi: 10.1016/j.hrtlng.2013.03.002. Epub 2013 Apr 10.

本文引用的文献

1
Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population.
Europace. 2009 Apr;11(4):489-94. doi: 10.1093/europace/eup034. Epub 2009 Feb 14.
5
Review of the Registry's second year, data collected, and plans to add lead and pediatric ICD procedures.
Heart Rhythm. 2008 Sep;5(9):1359-63. doi: 10.1016/j.hrthm.2008.07.015. Epub 2008 Jul 22.
6
Prognostic importance of defibrillator shocks in patients with heart failure.
N Engl J Med. 2008 Sep 4;359(10):1009-17. doi: 10.1056/NEJMoa071098.
8
Subcutaneous bioimpedance recording: assessment of a method for hemodynamic monitoring by implanted devices.
J Cardiovasc Electrophysiol. 2009 Jan;20(1):76-81. doi: 10.1111/j.1540-8167.2008.01271.x. Epub 2008 Aug 6.
9
Continuous hemodynamic monitoring in patients with pulmonary arterial hypertension.
J Heart Lung Transplant. 2008 Jul;27(7):780-8. doi: 10.1016/j.healun.2008.04.009. Epub 2008 Jun 2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验